2024年1月3日发(作者:千里马汽车多少钱)

Room Air ConditionerWall-Mounted Inverter Heat Pump房间空气调节器挂壁式变频热泵型使用安装说明书OPERATING AND INSTALLING INSTRUCTIONSR410A製品名MSZ-YK09VA-H1MSZ-YK12VA-H1MSZ-YK18VA-H1目 录安全事项.............................1各部件名称...........................3操作前的准备工作.....................5“I?”(体感...)自动运转?....6选择运转模式时(製冷、除湿、製热、送风)..7动态地面测温控製操作.................8动态地面测温传感器的测温方向设定.....9风速·风向的调节.....................10睡眠模式运转.........................12凉感控製运转.........................13定时器运转(定时开·定时关).........13空调机长期不使用时...................14维护.................................14前面板的清扫.........................14过滤网的清扫.........................15在请维修人员之前,请再次检查以下项目.16当您认为「发生故障」时...............16

移机·检查...........................17安装安全事项.........................17安装说明.............................20CONTENTSSafety precautions .....................................27Part name ..................................................29Preparation before operation .....................30\"\" Auto Operation .........................32Manual operation (Cooling, Dry, Heating,Fan) ...........................................................33

\"MOVE EYE\"CONTROL OPERATION ......34AREA SETTING ........................................35Air flow velocity and direction adjustment

37Sleep operationEcono Cool operation .......38Econo Cool operation ................................39Timer operation (OFF TIMER-ON TIMER) ...39When the air conditioner is not used for

a long time .................................................40Maintenance ..............................................40Front panel cleaning ..................................40Filter Cleaning ...........................................41

Please check the following items

before connecting 42When you think trouble occurs ..................42Removal and inspection ............................43Safety precautions for Installation .............43Installation instructions ..............................46请不要将空调器电源插头与其它自发供电设备连接。如果连接将可能造成空调器损坏。 警告如果处置错误,造成死亡、重伤结果或财产损?失的可能性很大。 注意如果处置错误,可能造成空调机不能正常使用或造成损失。安装结束后,请安装人员务必在安装结算联和保修卡上按要求贴好条形码。非常感谢您选用三菱电机房间空调器。·为了确保正确安全地使用本机,在使用前,请一定先阅读说明书。阅读以后请妥善保??存,以备必要时查阅。·购买机器时,须在出售店收取记载有「购买日期·店名」的有效证明。·顾客请不要自己安装机器(自行安装,将不能保证安全和功能,由此引起的安全问题??本公司不予负责。自行安装机器的售后服务不属于三包范围)。

安全事项·使用前,一定请先详读此「安全事项」。·这里所示的注意事项,是一些有关安全的非常重要的内容,一定要遵守。文中所用“图符号”的意思如下?:绝对不可做。?:一定请按指示做。?:禁止插进指头或棒条等。?:禁止踩到室内/室外机组上面或在它们上面堆放东西。·阅读后,请收藏在使用者容易发现的地方,以便参考。·儿童或虚弱者必须在监护人协助下才可使用本空调器。?:有触电的危险请小心。?:一定请拔下电源线插头。?:一定请关闭电源。?:一定要接地线。

警告禁止在电源线的中途引线或延长电源线及禁止使用多孔插座。·可能因接触不良、绝缘不良、超过容许电流量而会引起火灾、触电事故。禁止损伤电源线或作连接加工等。·若在电源线上堆放重物,以及损伤、或加热连接加工电源线,便有可能损坏电线引起火灾或触电事故。运转中,禁止拔下电源插头。·可能产生火花,引起火灾事故。·用遥控器关闭室内机组后,一定请关闭保护开关或安全拔下电源插头。不要长时间让冷风直吹肌肤。·可能会损害身体健康。不要自己安装机器。·因为若安装不当,将可能引起火灾、触电、机器掉落伤人或漏水。请与出售店或技术服务中心联系。禁止在放置或使用挥发性、腐蚀性、可燃性化学製品的环境中使用空调。·在室内使用挥发性、腐蚀性、可燃化学製品(如二甲苯、香蕉水、甲醇等)期间,必须禁止使用空调。·室内装修油漆未干,必须打开门窗,进行通风,等房间内各种稀释剂气体挥发散尽,方可使用空调。??否则会引起机器腐蚀,变形,甚至引起火灾。禁止燃烧器具放在直接吹得到风的地方。·可能引起燃烧器具的不完全燃烧。禁止用杀虫剂·消毒剂·可燃性喷雾材料喷吹。·可能引起火灾、变形。安装台如果已陈旧不堪,不可置之不理。·机组有翻倒伤人的可能。保养机组时,禁止站在不稳固的脚台上。·可能跌倒受伤。禁止拉电源线。·要卸下电源线时,必须抓住插头拔下。因为可能拉断电源线中的一部分芯线而引起火灾事故。禁止在进风口、排风口或出风口插入手指或棒条等。室内机安装高度应保证风叶叶片高于地面2.5米以上。·里面有高速旋转的风扇,会造成人身伤害。·应看好儿童,切勿让他们玩弄空调器。发觉异常时(有糊味等),应立刻停止运转,拔去电源插头并关闭电源开关。·发觉异常而继续运转下去时,可能导致火灾、故障等。此时,请与出售店或技术服务中心联系。清除电源插头上的灰尘,接插稳固。·若附着灰尘,或没有插好,便有引起火灾、触电的可能。和燃烧器具一起使用时,应该时常换气。·可能产生氧气不足的现象。长期不使用机器时,应拔下电源插头。·因堆积灰尘而有可能引起火灾和事故。禁止踩在室内/室外机组上或在上面堆放东西。·可能跌下受伤或机器掉落伤人。不可自己修理或移机。·因为处理错误,可能导致火灾、触电、机器掉落伤人或漏水等。请与出售店或最近技术服务中心联系。·如果电源线损坏,必须由製造商或服务商更换,以避免损失。1

安全事项 注意在拆卸过滤网时,小心不要碰到室内机组的金属部分。·有被刮伤的可能。禁止在直接吹到空调机气流的地方放置动植物。·可能对动植物有不良影响。禁止给电池充电或拆卸电池,禁止投入火中。·可能导致电池漏液、火灾或爆炸。禁止开放着门窗,在高湿度状况下作长时间的运转。·开冷气时,若在高湿度(80%以上)下作长时间连续运转,空调机可能有冷凝水滴下,浸湿污损室内家具。禁止当其他特殊用途。·不能作为保存精密机器、食品、动植物、美术品的用途。因为有降低保存品质量的可能。打扫时,应停止运转,拔下电源插头或关闭电源开关。·运转中,有高速旋转的风扇可能伤人。更换相同类型的2节新电池。·新旧电池混用可能导致电池发热、漏液或爆炸。如果电池液沾到皮肤或衣服,请用清水仔细清洗。·如果电池液不慎溅入眼睛,请用清水冲洗并立刻就医。禁止用潮湿的手去操作开关。·有触电的危险。禁止用水洗刷空调机。·机器中如果进水,会降低绝缘性能,有发生触电的危险。安装机器

警告·安装机器,请与购买机器的出售店或技术服务中心联系。 注意禁止安装在有可能泄露腐蚀性、可燃性气体的地方。·万一气体泄露并聚集在机组周围时,便有发生爆炸或损坏机器的危险。室内外机组下面不得堆放其它电器产品及家具等。·因会有水滴滴下的情况,导致污损和设备故障。必须接地线。·空调插座应连接有专门接地线,地线切勿接到煤气管、自来水管、避雷针导线、电话接地线上。如果没有接??地线或地线没有连接好,可能引起触电事故。在使用前请务必确认是否有接地线和接地线是否按要求连接。某些安装场所(例如湿气高的地方等),必须安装漏电断路器。·若不装漏电断路器,便可能有触电的危险。排水口须保证能顺利排水。·如果有排水不良状况,机组将可能滴水浸湿污损家具。2

各部件名称室内机组主机前面板热交换器进风口上下导风板左右导风板出风口显示区域(详见下图)过滤网显示区域运转指示灯测温方向设置指示灯应急运转开关遥控器接收部动态地面测温传感器室外机组进?风?口???(背面·侧面)配????管???排水软管排?风?口 室外机组排?水?口3

各部件名称遥控器信号发射部如何安装电池及设定当前时间1移去前盖,装入电池。重新装好前盖板。先插入电池的负极。检查电池的极性是否正确。操作显示部分先插入电池的负极。运转/停止(开/关)按钮风扇速度控制按钮运转模式选择按钮凉感控制按钮睡眠运转控制按钮地面测温广角送风按钮(左右导风板按钮)测温方向按钮温度按钮上下风向控制按钮定时关按钮定时开按钮时间设定按钮增加按钮减少按钮时钟设定按钮复位按钮2按下复位按钮。用尖细东西按下。??如果复位按钮未按下,遥控器不能正常使用。??注意按下时不要太过用力。用尖细东西按下。3按下时钟设定按钮。4按下(增加)与(减少)按钮(时间设定按钮),设置当前时间。每按下一次前进按钮,时间增加1分钟。每按一次后退按钮,时间减少1分钟。长时间按住按钮,设定时间会以10分钟等级增加/减少。5再次按下时钟设定按钮,并合上前盖板。重要设定动态地面测温传感器使用前遥控器的设定■在遥控器电池盒内请将滑动开关拨到适当位置(要求和室内机安装的空间位置一致)如果这个开关没有设定正确,那么空调器可能不能达到最佳的运行状态。开关(安装位置)开关的位置左中右遥控器的显示室内机组安装在房间的哪个位置?安装在左面安装在中间(要求距离50cm以内)(左)(中)安装在右面(要求距离50cm以内)(右)注:如果室内机组安装在距离侧面墙壁或橱柜或其他附近对象超过50cm时,设定此开关在“中间”位置。4

操作前的准备工作遥控器的使用方法·信号可到达范围是对着室内机组正面的直线距离6米以??内。·按下按钮时,室内机组将发出“哔”或“哔哔”收到信??号的声音。???如果没此响声,请再作一次按钮操作。·遥控器必须小心使用。如果它掉落地上,抛掷或浸了水,??就可能出现不能发送信号的情况。电池更换电池的标准以下情况需要更换两节新7号碱性电池(LR03):·室内机组对遥控器信号无反应时。·遥控器上的显示器变淡时。??请勿使用锰电池。遥控器会发生故障。·碱性电池寿命大约1年。但要考虑干电池底面的建议期限??(年/月)。如果接近期限,则必须尽早更换电池。·为防止漏液,长期不使用遥控器时请将电池取出。 注意:如果电池液沾到皮肤或衣服,请用清水仔细清洗。如果电池液不慎溅入眼睛,请用清水冲洗并立刻就医。·请勿使用充电电池。·2节电池须属同种电池。·废旧电池应妥善处理。自动重新启动功能该机型具有自动重新启动功能,但在工厂出货时,此功能设为关闭。如您需要使用自动重新启动功能,请与技术服务中心联系。自动重新启动功能就是...当使用遥控器控製室内机组时,机组自动记忆运转模式,设定温度和风扇速度。如果运转过程中发生断电或关闭了主电源,当电源恢复后“自动重新启动功能”会自动启动机器并以断电前用遥控器设定的模式运转。?室内机组将电源插头插入插座,将电源开关推到开的位置。 警告:须清除电源插头上的灰尘,确认接插稳固。如果附着有灰尘或插座不良时,将有发生火灾,触电的危险。5遥控器不能使用时(应急运转)当遥控器的干电池电量耗尽,或遥控器发生故障时,可利用本机上的应急运转开关控製运转。1按下应急运转开关。·?每按下一次按钮,即按照製冷→製热→停止模式的顺???序变化。·运转模式由室内机组上的操作指示灯指示。如下图所示。 操作指示灯运转模式操作指示灯应急製冷测温应急製热测温停止测温

注意:这是在应急模式下的显示内容。在应急模式下测温方向的设定无效。·运转内容如下。在最初的30分钟内不受房间温度影响只连续运转,风速恒定。运转30分钟后状态如下:运转模式製冷製热设定温度24℃24℃风速中中上下导风板自动自动左右导风板前前2要停止时,请按下应急运转开关,设定为停止。·每按下一次按钮,即按照製冷→製热→停止的顺序??变化。

“”(体感...)自动运转“(体感...)”自动运转模式下,一次操作就可自动使室内环境条件达到最佳状态。开始体感自动运转时■按下 按钮。??显示??(自动运转)时,空调器自动控製为最适当温度。要停止时■请按下 按钮。开始运转后大约经过15分钟:如果感到太热:■按下 按钮降低温度。??每按一次,大约下降1℃。如果感到太冷:■按下 按钮升高温度。??每按一次,大约上升1℃。不显示“(体感...)”自动运转时,请按??按钮以设定自动运转模式。每按一次,运转模式即按照(自动运转)→(製冷)→(除湿)→(製热)→(送风)的顺序变化。(自动运转...)模式自动运转的结构根据开始运转时的室温,运转模式自动设定为製冷、除湿或製热。但在停机后2小时以内再运转时,则将与上次运转进行同样内容的运转。一旦设定好运转内容后,室温虽有变化也不受影响。运转内容如果不喜欢,可按下??按钮,再选择适当的运转内容。体感自动运转内容开始运转时的室温大约25℃以上大约25℃以下大约23℃以下运转模式製冷除湿製热目标温度(初始状态)大约24℃-大约26℃注:製冷:当室温高于设定温度2℃时,设定温度不会变化,因为空调器正在运转到达目标(设定)温度。??????此时,请等待室温降至设定温度附近2℃以内,然后改变设定温度。製热:当室温低于设定温度2℃时,设定温度不会变化,因为空调器正在运转到达目标(设定)温度。??????此时,请等待室温升至设定温度附近2℃以内,然后改变设定温度。6

选择运转模式时(製冷、除湿、製热、送风)选择运转模式时(製冷、除湿、製热或送风模式):12请按下

按下

按钮。 按钮选择运转模式。每次按下按钮,运转模式即作(自动运转)→(製冷)→(除湿)→(製热)→(送风)。要停止时:■请按下 按钮。??运转模式设定,以后只要按??按钮,空调机即以设定模式进行运转。■要改变设定温度时:·要降低温度时,请按下??按钮。按一次,大约下降1℃。·要升高温度时,请按下??按钮。按一次,大约升高1℃。除湿运转时·不能进行温度控製(温度设定)。·以稍低于室温的温度进行运转。注:·环境温度太高时,因为製冷运转负载太大的关系。室内温度可能无法达到设定的温度。·热泵型空调器原理:机器通过冷媒循环从室外空气中吸收热量并将其传送到室内从而加热房间内的空气,其製热的能力随室外气温降低而下降。·如室外温度变得很低,请与其它取暖设备一起使用。使用空调须知製冷如何让製冷运转更有效率①关紧窗户,放下窗帘,减小日照量。②在窗玻璃上贴市售的热线遮蔽用薄膜,也可以减少阳光进入室内的热量。③室外机组安装在不易受太阳直射的地方。製热有益健康的暖和度,其关键是和外界的温度差!要进行製热运转时的温度设定,应和外界温度不要相差太大。虽然随地区而有不同,但是,一般可把设定温度定在20℃-24℃。除湿70%是人们感觉舒适的湿度分歧点。人觉得闷热时,是因为空气中的水蒸汽含量多,即湿度高的关系。湿度与温度、风都有关系。一般认为人感到最舒适的湿度条件是夏季60%~75%,冬季55%~70%。7

动态地面测温控製操作...智能化的温度控製方式本空调器对温度的调节控製(“智能化的温度控製”)是除了检测房间温度以外还同时检测地面/墙面的辐射温度从而使得空调器进行综合调节控製的过程(“动态地面测温控製操作”)。取消动态地面测温控製操作后以往的房间温度控製方式代替智能化的温度控製。?开始动态地面测温控製时在手动冷房或手动暖房的模式下,用尖细东西按下遥控器上地面测温按钮。注意:这个动态地面测温控製操作模式是有记忆的(即使交换电池或按下复位按钮),当遥控器初次使用时要进行设定,再使用时根据前次设定方式进行运转。解除动态地面测温控製时再一次用尖细东西按下遥控器上地面测温钮。注意:如果此空调器是关机状态则不能取消动态地面测温操控製操作,必须在运行状态下进行解除该模式的操作。动态地面测温控製操作本传感器经常测温地面/墙面的辐射温度,通过估计温度(实际上是对房间内部人体的感知)自动地调整设定温度。(“智能化的温度控製”)优势房间内很快形成舒适的环境。当空调器保持长时间运转时,房间内将不会感觉太冷或太热。湿度大约20%大约50%地面温度墙面温度房间温度大约30%智能温度控製智能温度控製的优势墙面温度/地面温度房间温度/空气温度动态地面测温传感器当测温方向设定记忆取消时,根据空调器安装位置的不同方位动态地面测温传感器检测范围也不同。安装位置安装在左面安装在中间安装在右面检测范围图示。传感器检测方向右面中间左面大约150范围内请查阅第4说明(遥控器电池盒内滑动开关设定)o这个测温方向设定是有记忆的(前次设定状态),这个全方位测温传感器在150的范围内(三种安装空间之一,左面/中间/右面)检测地面/墙面的辐射温度,因此,检测到的温度可能会不同,由于标准温度(接近于市售温度计所测值)是依靠接近房间或接近地面和/或墙面的温度来分类。保养或维修之后请正确安装前框组件,这样才能正确地检测地面/墙面辐射温度。8

动态地面测温传感器的测温方向设定在测温方向设定时,水平空气流动的方向(左右导风板)将根据传感器检测地面/墙面的辐射温度来自动调节。开始测温方向设定时按下“测温方向”按钮连续按该按钮,显示是按下列顺序变化。自动→左面→右面→取消(恢复设定前的设置)。这个动态地面测温传感器间歇地转动来检测地面和墙面的辐射温度。注意:测温方向设定只有在动态地面测温控製操作时才有作用。(查阅第8页)如果这个测温方向设定被取消,左右导风板将返回测温方向设定前的设置。水平空气流动方向(左右导风板),在测温方向设定使用时将不能手动设置。如果测温方向设置是设定在製热操作时,当室内地板和墙面的辐射温度较低时室内机组会自动的在该区域内输送温暖的风。如果测温方向设置是设定在製冷操作时,当室内地板和墙面的辐射温度较高时室内机组会自动的在该区域内输送凉爽的风。例:在製热操作时左右风向的移动白天温暖的区域晚上寒冷的区域室内机组在房间内检测到寒冷的区域时会输送温暖的风。室内机组显示注意测温方向设定显示如果这个动态地面测温传感器检测到大约有3℃温度差异时那水平空气的流动方向(左右导风板)将改变。测温方向设定在自动档时,当房间温度是较均匀时左/右两个显示灯都点亮。测温方向设定的解除按下测温方向按钮(选择取消)在测温方向设置期间当左右风向按钮按下时,测温方向设置将解除。室内机组安装的位置和空气调节的空间安装在左面安装在中间安装在右面左右左右左右确认遥控器内滑动开关的设定位置一定要与室内机组安装的位置一致。如果这个开关设定不正确,那么将影响空调器的使用功效。(查阅第4页)9

动态地面测温传感器的测温方向设定测温方向设置遥控器按钮优先对房间内左侧空气调节。对整个房间空气调节。优先对房间内右侧空气调节。按下测温方向按钮(选择左侧)按下测温方向按钮(选择自动)按下测温方向按钮(选择右侧)安装在中间左右风向的控製范围(上下风向的位置不变)安装在左面安装在右面室内机显示测温方向测温测温测温风速·风向的调节选择喜欢的风速及风向。■要改变风速时,请按下 按钮。??每次按下按钮,即按照(弱)→(中)→(强)→(超强)→(自动)的顺序改变风速。风速的选择方法:本空调原理上:风量越大,节能效果越好,噪音也越高,製冷时出风温度升高,製热时出风温度下降。因此,选择(弱)档可获得一个安静的休息环境,选择(强)或(超强)档可得到好的节能效果。■要改变上下的风向时,请按下 按钮。??每次按下按钮,即按照→(1)→(2)→(3)→(4)→(摆动)→(自动)的顺序改变上下风向。摆动送风摆动运转可使气流到达整个房间。上下风向的推荐范围:平常请用?(自动)。製冷或除湿请用?①?或②位置。製热时请用位置?②?至?④。製冷除湿製热10

风速·风向的调节上下导风板的移动製冷/除湿製热运转的开始製热自动①①①水平位置极小气流④空气变热时……④④④④水平位置①①位置(4)·导风板停止摆动后自动移动至水平位置。??注:??气流高于位置(1)。·空调机开始运转后,导风板停止在水平位置。一旦室内机组出来的气流温度够高,导风板移动至位置(4)。·一旦空调机开始运转,风扇速度随室内机组出来的气流温度变热而逐渐增加,直至到达设定速度。製热运转的开始手动②②③③④④0.5至1小时后①①①②④④④②③风向设定为位置(2)、(3)或(4)④②②②③①③③①②②②②水平位置空气变热时……极小气流设定位置位置(1)或(2)·运转大约一小时后,空调机自动把导风板移??动至位置(1)或(2)。要将风向改回原始设定,??请再操作遥控器上的导风板按钮。·导风板在位置(1)和(4)间间歇移动。导风板在??位置(1)和(4)上停留片刻。摆动·空调机开始运转后,导风板停留在水平位置。一旦室内机组出来的气流温度够高变得够热,导风板移动至对应气流设定方向的位置。·一旦空调机开始运转,风扇速度随室内机组变热而逐渐增加,直至最后到达设定速度。·导风板在位置(2)和(4)间间歇移动。导风板在位置(2)和(4)上停留片刻。②②①②④②④②④④④④注:·请用遥控器调节风向。用手移动上下和左右导风板可能造成故障。·运转模式改变至“(自动)”模式时,上下导风板自动改变至各模式中的位置。■要改变左右风向,请按下 按钮。??每次按下按钮,左右导风板角度按照以下顺序变化:??(摆动)摆动送风使用摆动送风可使风到达房间每个角落。11

睡眠模式运转要休息时,请在製冷模式中选择此功能。要选择睡眠模式时1机组运转时按下 按钮。风扇速度改变为自动。当改变风扇速度时,睡眠模式取消。按下 按钮或 按钮设定睡眠模式温度。设定睡眠模式温度后,再次按下??按钮会显示前一模式设定的温度。要解除睡眠模式2■再次按下 按钮。??按下?、?按钮或改变运转模式也能解除睡眠模式。??睡眠模式可与定时开/关结合使用。

睡眠模式说明按下??按钮时,显示部变暗,风扇速度自动转为自动模式,空调器低噪音运转。·以睡眠模式运转时,有时空调器製冷或製热力度不够。这时,可解除睡眠模式。製冷/製热模式空调机以按下睡眠按钮前设定的温度运转大约30分钟,然后切换至睡眠模式所设定的温度。设定温度改变睡眠模式设定温度製冷模式中,建议将温度设定为比当前温度稍高1℃至2℃,避免睡眠中着凉。製热模式中,建议将温度设定为比当前设定的温度低5℃至6℃睡得舒适。按下睡眠按钮前设定的温度(大约30分钟)按下??按钮睡眠模式设定温度如果使用定时开启动睡眠模式,空调器在睡眠模式所设定的温度上开始运转。定时开设定温度遥控器初始设定温度如果更换电池后遥控器复位,初始温度设置如下:製冷睡眠模式:28℃製热睡眠模式:17℃睡眠模式设定温度定时开结合睡眠模式。12

凉感控製运转要享受健康舒适、省电的製冷运转时,请使用此模式。在手动製冷模式运转中,请进行以下操作。■按下??按钮。??选择以??(凉感)控製模式运转的空调机,将根据空调机出风口温度控製上下导风板作周期性地自动摆动。??另外,设定温度也从製冷运转时自动升高2℃。要解除凉感控製运转:■请再按一次??按钮。?按钮或改变运转模式,凉感控製解除。·在凉感控製运转中,按下?·??按钮、?或??按钮及定时开/关按钮可继续使用。什么叫“凉感控製”?摆动气流(气流变化)比恒定气流更为凉爽。因此即使设定温度自动设定为高2℃,也能得到舒适感。从而节省了电力。定时器运转(定时开·定时关)可预设在就寝后或您回家时或起床时开/关空调器。如何设置定时开如何设置定时关”?图形闪烁。 (增加)和 (减少)设定定时器时按下 按钮。按定时关按钮?“1按下 按钮。按定时开按钮?“2使用时间按钮

”?图形闪烁。间。每按一下??按钮,设定时间增加10分钟;每次按一下??按钮,设定时间减少10分钟。解除定时开请按下 按钮。使用时间按钮 (增加)和 (减少)设定定时器时间。每按一下??按钮,设定时间增加10分钟;每次按一下??按钮,设定时间减少量10分钟。解除定时关定时开·定时关结合使用时按下 按钮。定时开和定时关结合使用。先到的设定时间先运转。(“↑↓”标记指示定时器的运转顺序)·如果未设定当前时间,定时器运转可能不能使用。注:如果定时器运转时主电源关闭或发生电源故障,定时器设定取消。13

空调机长期不使用时长期不使用时要再开始使用时1实施风扇运转3~4小时,让空调机内完全干燥。2关掉电源开关然后拔掉电源线插头。 警告:空调机长期不使用时拔下电源插头。因为可能堆积灰尘而引起火灾。·要进行风扇运转时,请设定为送风运行模式并选择最??高设定温度。1清扫过滤网并装回本机。(清扫的方法,请参见第15页)2室内及室外机组进风口、排风口须确认是否被遮蔽了。3确认接地线是否牢固。 警告:3取出遥控器中的电池。?注意:为防止漏液,遥控器长期不使用时取出所有电池。要接地线。地线不可接在煤气管、自来水管、避雷针、电话线上面。若不按要求接地线,可能有触电危险。维护清扫之前关闭电源开关然后拔下电源插头。室内机的清扫用柔软的干布清洁。·如有明显污渍,用布蘸中性清洁剂的水溶液擦拭机组。·严禁使用汽油、挥发油、磨擦粉、或消毒剂。否则会损坏机组。·前面板举过水平位置后可能脱落。如果前面板脱落,请参考“前面板的清扫”中步骤3。 警告:清扫时,必须停止运转,拔下电源插头并关掉电源开关。因为运转中,高速旋转中的风叶可能造成人身伤害。前面板的清扫按住并松开前面板两端的卡扣,提起前面板,直至听到“咔哒”声(①)。握住铰链,水平提起前面板,向前拉出铰链并拆下面板(②)。用柔软的干布擦拭或水洗。水洗后,用柔软干布擦干净水。·如果面板太脏,可用布蘸加入中性洗涤剂的温水溶液擦拭前面板。·严禁用汽油、挥发油、混合溶剂、摩擦粉或消毒剂,请勿用刷子或硬面海绵清洗。·请勿长时间(两小时以上)置于热水中或置于直射阳光及取暖器作用范围内,否则会导致前面板变形及变色。用两手握住前面板的两端,把前面板大致水平放置,再把铰链部放入室内机最上部的槽中,直至听到“咔哒”声为止。接着关上前面板,再用手按一下下图箭头所示的三个位置。 警告:·不要强行抽出前面板,不要掉落,否则会造成前面板破 损。·拆装前面板时,不要站在不稳定台面上,否则有可能翻 倒受伤。14

过滤网的清扫过滤网的清扫(以两个星期一次为标准)1轻轻拉出过滤网①?打开前面板,向上推出小卡钩高效过滤网空气过滤网②?向下拉出过滤网小卡钩③取出高效过滤网????手指通过空气过滤网上的缺口捏住高效过滤网,按箭头方向抽出。缺口手指通过空气过滤网上的缺口捏住高效过滤网,按箭头方向抽出。注意:拆卸过滤网时,请注意别碰到室内机组的金属部本品可用吸尘器清理分,因为有被刮伤的可能。2可用吸尘器清扫或用水洗涤干净。·不可水洗,清洗空气过滤网时,一定要取下高效过滤网。?禁止用刷子或硬面海绵清扫。否则过滤网会变形。·更换年限约2年半(以北京地区为例),由于各地区空气?如果过滤网太脏,可用加入中性洗涤剂的温水洗涤溶液洗刷。 质量不同会有差异。?禁止用热水(大约50℃以上)清洗,以免变形。 根据使用房间的环境可能会缩短使用寿命,特别是附着了用水洗涤过后,阴干后才能使用。?禁止用阳光干燥或用火烘干。空气过滤网 香烟烟油和厨房油污等情况下请及时更换。·高效过滤网型号:S-MAC-621YK。 本品为一次性产品34安装过滤网①?安装高效过滤网?????将高效过滤网按箭头方向装入空气过滤网中。高效过滤网?????请确保空气过滤网的卡钩扣住高效过滤网。卡钩高效过滤网高效过滤网空气过滤网空气过滤网②?沿轨道向上插入过滤网③?将小卡钩向下插入,卡紧过滤网缺口缺口手指通过空气过滤网上的缺口捏住高效过滤网,按箭头手指通过空气过滤网上的缺手指通过空气过滤网上的缺方向抽出。口捏住高效过滤网,按箭头口捏住高效过滤网,按箭头小卡钩方向抽出。方向抽出。本品可用吸尘器清理本品可用吸尘器清理本品可用吸尘器清理 本品为一次性产品·不可水洗,清洗空气过滤网时,一定要取下高效过滤网。 本品为一次性产品 本品为一次性产品·更换年限约2年半(以北京地区为例),由于各地区空气·不可水洗,清洗空气过滤网时,一定要取下高效过滤网。·不可水洗,清洗空气过滤网时,一定要取下高效过滤网。 质量不同会有差异。·更换年限约2年半(以北京地区为例),由于各地区空气·更换年限约2年半(以北京地区为例),由于各地区空气 根据使用房间的环境可能会缩短使用寿命,特别是附着了 质量不同会有差异。 质量不同会有差异。 香烟烟油和厨房油污等情况下请及时更换。 根据使用房间的环境可能会缩短使用寿命,特别是附着了 根据使用房间的环境可能会缩短使用寿命,特别是附着了·高效过滤网型号:S-MAC-621YK。 香烟烟油和厨房油污等情况下请及时更换。 香烟烟油和厨房油污等情况下请及时更换。·高效过滤网型号:S-MAC-621YK。·高效过滤网型号:S-MAC-621YK。155高效过滤网的维护

在请维修人员之前,请再次检查以下项目是否出了故障?检查点是否出了故障?检查点?空调机无法运转。·电源开关是否打开?·保险丝是否烧断?·是否设定了定时开?上下导风板不动作。??·上下导风板和左右导风板是??否正确安装于室内机组?·风扇防护网是否变形?·温度设定是否正确?·过滤网是否干净?·室内或室外机组的进风口或??出风口是否被遮蔽?·门窗是否打开?室内机组发出臭味。·过滤网是否干净?遥控器不显示或变·电池电量是否用完?暗。室内机组对遥·电池极性是否装反?控器信号无反应。·是否按下了其他电器遥控器??上的按钮?检查上述项目后空调机仍无法恢复运转,请停止使用并与机器的出售店或技术服务中心进行联系。在要求维修之前,请注意下列情况。·在使用电子式荧光灯的房间里,有可能不能接受遥??控信号。·在无线电电波弱的地方,空调机可能干扰广播或电??视接收。受影响设备可能需要放大器。·打雷时,请停止运转并拔下电源插头或关掉电源开??关器。否则,可能有损伤空调电气部件的危险。室内无法充分製冷。当您认为「发生故障」时是否出了故障?答案(不是异常)重新开机3分钟内·根据微型电脑的指示以保护空调空调机仍无法运机。请等待。转。听到“噼啪”声。·由于温度变化,前面板的膨胀?/收缩产生声音。室内机组出来的空·空调机可能吸入了墙壁、地毯、家具、衣服等的异味,再混合空气有臭味。气吹出。·可视光触媒过滤网是否清扫。如果可视光触媒过滤网积满灰尘,请清扫。除湿运转模式中风·除湿运转中,机组使用与製冷运转相同的製冷剂回路.除湿运转为了扇停止。降低湿度而不致于降低室温,压缩机有时会停止,此时室内风扇停转。这是为了防止热交换器上的凝露水滴再次蒸发。?·这是空调机内製冷剂流动发出的听到水流声。声音。·这是热交换器内凝露水滴流动发出的声音。·这是热交换器解冻发出的声音。听到类似气泡的·这是开启吸油烟机或通风扇时,从排水软管吸入外部空气,使排水软声音。管内水流喷出而发出的声音。如果外部风力很强,外部空气吹入排水软管,也会听到这种声音。运转中室内机出风·空气中的水份遇到从室内机出风口吹出雾气。口里吹出的冷风而迅速凝结成雾气所至。可从室内机组听·这是风扇或压缩机开关正在切换到“咯嗒咯嗒”声(接通断开)的声音。音。室内机发出“布·这是空调机启动或停止冷媒流动的声音。嘘!”声。是否出了故障?答案(不是异常)运转中自行改变风·当空调机在製冷模式中运转时,如果空气向下吹持续1小时,风向向。遥控器无法调节上自动设定为位置(1)或(2),这是为了防止凝露水滴滴下。下导风板方向。·製热运转中,如果吹出空气的温度较低,或是在除霜运转时,将自动地设定水平方向吹出。室外机组有漏水现象。·製冷运转中,管道或管道接头部分·这是因为在製热运转时或除霜运将因冷却而引起水份冷凝。转时,会流出溶化的水或水蒸气的缘故。·因为製热运转中会滴下附着在热交换器上的水滴。·製热运转中,解冻操作产生蒸气室外机组放出白烟。看似白烟。刚开始製热运转中·正在准备能吹出足够温暖的风。就时,不会马上就吹这样请等候。风。製热运转中停止运·正在溶化室外机组上的结霜。(除霜运转)最长10分钟就完了,就这转大约10分钟。样请等候,(户外气温低而湿度又高时,便会结霜。)左右和上下导风板·这是为了正常执行左右和上下导暂停摆动送风又重风板的摆动送风。??新开动。有时听到“嘶·这是空调机内部製冷剂切换流向发出的声音。嘶”声。房间不能充分製冷·排风扇或液化灶具使用时,製冷负荷加重,导致製冷效果不足。和製热。·室外气温太高或太低时,製冷或者暖效果不足。16

移机·检查检查维修■?空调机用过几年之后因内部肮脏。性能将减低。■?因使用状况而可能发生臭味,或因堆积尘垢而造成冷凝水的排水不良。■?与普通的检查维修不同.最好请专门技术人员为您服务。请与本空调机的出售店或技术服务中心联系。运转噪声问题也须考虑内要移机时■?室外机组的排风口附近不可堆置东西。■?因增改建房间,迁居而须拆卸下空???因为将会减低机器效能也可能增大运???调机及再安装时,必须找专门技术转噪声。???人员为您服务。■?运转作用中,如果发生异常声,即请与本空调机的出售店或技术服务中心联系。 警告:用户请不要自己修理或移设空调机。如果处理不当,便有发生火灾、触电、机组掉落伤人、漏水等危险。如製冷剂中有空气等物质混入,会导致压力升高,发生破裂等。因此请于本空调机的出售店或技术中心联系。安装安全事项1.为确保安全,请注意下列各项 警告用户不可自行安装。如果安装不妥,可能引起火灾、触电、零件掉下伤人或漏水等。请与销售店或技术服务中心联系。 警告安装或移机时製冷剂回路中不能混入除製冷剂以外的其他物质。如果空气等物质混入会导致系统压力升高、发生破裂等。机器必须安装在能承受相当重量的地方。如果安装在强度不够的地方,将有机组掉下伤人的危险。安装或移机时切勿封入指定以外的製冷剂。若封入指定以外的製冷剂,可能成为运转不畅、误动作、机械故障等问题的起因,有时甚至有发生重大安全问题的可能性。室内外机组之间的配线,须使用规定的电线连接妥当,并使接线端子不直接受到外力的影响确实固定好。连接或固定不好,可能引起火灾事故。回收製冷剂时,在拆下连接管前先关闭压缩机。如果当压缩机运转并截止阀开启时,拆下连接管会有空气混入,会造成系统压力异常升高,造成管子爆裂或引起伤害。安装工作必须根据安装说明书准确地实施。如果安装得不妥,可能引起火灾、触电、零件掉下伤人或漏水事故。装机时,在启动压缩机前确保管子安全的连接。如果在管子连接完成前,并在截止阀开启时运行压缩机,会有空气混入,会造成系统压力异常升高,造成管子爆裂或引起伤害。安装施工中如发生製冷剂泄漏,请进行换气。製冷剂与明火接触会产生有毒气体。电气施工应按照安装说明书实施,请一定要使用专用电路电源。电源电路如果容量不够或施工不完全、可能发生火灾或有触电的危险。17

安装安全事项 警告室内机组的电气盖和室外机组的维修板须确实安装好。室内机组电气盖和室外机组的维修板如果不装好,则可能因为灰尘、水份进入而造成火灾或触电危险。安装施工用部件,必须使用附带的和规定的部件。采用部件不当,可能引起火灾、触电、或机组掉下伤人、漏水等事故。电源线路的中途引线,使用延长电源线,或使用多孔插座线等都不可采用。接触不良,绝缘不良,或超载等都可能引起触电事故。须做接地施工。空调插座应连有专门接地线,如果没有接地线或地线没有连接好,可能引起触电事故。地线切勿接到煤气管、自来水管、避雷针导线,电话接地线上。禁止安装在有可燃性气体泄漏的地方。万一可燃性气体泄漏而聚集在机组周围,可能引起爆炸事故。应装有漏电保护器。如不装上漏电保护器,可能引起触电事故。请一定按照安装说明书进行排水和配管施工。排水和配管施工如果有不妥当的地方或室内机组倾斜将可能产生机组滴水弄湿、污损家具物品等情况。连接导线的中途引线是一定不可采用的。一定会产生机组误动作,造成机组无法正常运行。请严格按照GB17790《家用和类似用途空调器安装规范》进行空调器的安装。安装施工完毕后,须确认是否有泄漏製冷剂气体的地方。如果电源软线损坏,必须使用专用软线或从製造厂或维修部门买到的专用组件来更换。此外,如果还有不明白的地方,即请找机器的出售店联系。2.R410A製冷系统注意事项2-1 适用R410A製冷剂的空调器 警告使用C1220铜磷料(用于铜和铜合金製成的无缝管)连接製冷剂管。确保管内壁清洁,不含有硫化物、氧化剂、碎屑或灰尘等任何有害的赃物。务必使用指定厚度的管道。使用脂油、乙醚油、烷基苯油(少量)作为製冷剂油,涂在喇叭口的部分。如果把矿物油混入製冷剂油中,油质可能变差。切勿使用R410A以外的製冷剂。如果使用其它製冷剂,氯会使油变质。使用R410A製冷剂的专用工具。如下是R410A专用工具一览表,供参考。工具(用于R410A)压力表扩口工具加液软管尺寸测量器检漏仪真空泵转接头扭矩扳手电子秤务必使用正确的工具。如果灰尘、碎屑或水气进入製冷剂管,製冷剂油的油质可能变差。切勿使用简易加液钢瓶。如果使用简易加液钢瓶添加製冷剂,製冷剂的成分会改变,引起效率降低。2-2 使用R410A製冷剂设备的注意事项 警告安装或移动空调器时,务必使用指定的製冷剂(R410A)充注製冷剂管。切勿与其他製冷剂混合,管内也不要残留空气。残留在管内的空气在压力增大时,会使管道爆裂,并引起其他危险。液体管气体管MSZ-YK09/12VA-H1 6.35

厚0.8毫米 9.52

厚0.8毫米MSZ-YK18VA-H1 6.35

厚0.8毫米 12.7

厚0.8毫米切勿使用管壁比上述指定厚度薄的管道。真空泵切勿与R22製冷剂系统共用。18

安装安全事项3.选择安装位置3-1 室内机组·选择在进出气流不被挡住的地方。·选择吹出冷气可以到达房间各地方。·室内机组与室外机组最大距离及最大高度差:参考“极限管道长度”。·不至于发生振动的坚固墙壁上。·避免阳光直射的地方。·容易排水的地方。·距离电视机、收音机1m、电视天线3m以上的地方(否则可能干扰电视影像或产生噪声)。·尽可能远离日光灯、白炽灯处(否则可能使无线遥控不能正常地操作)。·可自由、方便地进行装、卸空气过滤网的地方。3-2 室外机组·选择受大风和大雪影响小的地方,如在严重降雪的区域内安装,请必须进行防雪处理(建议安装遮盖篷和/或底座机架)。·选择通风良好,灰尘少的地方。·不容易雨淋或阳光直晒的地方。·不要使运行噪音或吹出热风有妨碍邻居的地方。·为了不使运行噪音或振动增大,应牢靠地安装在牢固的机架上。·应避开有易燃气体泄漏危险的地方。·当机组安装在高处时,务必固定机脚。·务必水平安装。·便于保养维修。电视机或收音机等无线接受设备需距离室外机3m以上,如这样还有明显信号干扰时,可再加长相互间距离,以提高接受质量。电子式荧光灯为防止图像干扰和噪声,须距离1米以上安装。 注意请不要在下述容易发生故障的地方安装空调器。·机油等使用较多的地方。·海边等盐份较多的地方。·温泉地带。有硫化气体的地方。·其他环境大气有问题的地方。·避免安装在有挥发性、腐蚀性、可燃性化学品的地方。·吊车、船舶等移动的地方。19

安装说明1.安装简图及附件装箱单(在安装之前,请客户根据装箱单内容核对零件数量)零部件名称零部件名称数量数量安装代号安装代号1室内机

1室外机1安装板1室室2螺钉4×25毫米5

A32电池(7号)连接电线14B※1遥控器连接配管1C※内51外毛毡包扎带穿墙套筒1※D11保用证书墙孔盖?※E1使用安装说明书1管道包扎带F※延长排水软管1机机G1排水塞※1腻子室内机组Φ6.35室外机组Φ9.52Φ12.7(YK18-H1)维修口连接器截止阀极??限管道长度高?度?差弯管数量12米8米10米※ 此部品现地购置。·製冷剂调节…如果管道长度超出下表范围时,则需要补注製冷剂(R410A)。(加注有製冷剂的室外机组适用于以下管道长度以内。)管道长度超过6米需要添加製冷剂的量机型MSZ型(变频)30克×(冷气管长度(米)-6)扩口连接·本机组在室内和室外侧备有扩口连接部位。·如下图所示,製冷剂管道用于连接室内和室外机组。·说明:延长配管过长会导致製冷/製热能力下降。65毫米以上在左侧和左后侧配管时要有161毫米以上的空间(使用衬垫)140毫以上米1170毫以上米 注意(1)在寒冷的地区不要使用此排水管接头及橡胶塞,可能会因排水冻结而发生故障。排水管安装步骤(1)在底座上选择一个排水孔作为排水用,将排水管接头装在该孔上。(2)将排水管与排水管接头连接,为使排水顺畅,请保持排水管向下倾斜。25CEHD4310毫米以上20

安装说明外形安装尺寸进风口315±5.5350(单位:毫米)墙孔墙壁厚度直径65毫米(室内侧)(墙孔剖面)1厘米留出约1厘米,多余部分切除。排风口2-10×21长孔1-1 如何设定滑动开关(遥控器电池盒内)滑动开关的详细说明①移下遥控器正面下方的电池盒盖子②在遥控器电池盒内请将滑动开关拨到适当的位置(要求和室内机安装的空间位置一致)如果这个开关没有设定正确,那此空调可能不能达到最佳的运行状态.(图示参看第4页)注:如果室内机组安装在距离侧面墙壁或橱柜或其他附近对象超过50cm时,设定此复位开关在“中间”位置。③在电池盒内放入两节(AAA)1.5V电池。④关上遥控器正面下方的电池盒盖子。⑤用尖细东西(笔)按下复位按钮。2.室内机组的安装穿墙套筒C应始终使用穿墙套筒C,能避免室内和室外连接导线与墙内的金属部件接触,同时能防止鼠害。2-3 电源和连接电线规格·应使用空气调节器的专用电缆。滑动开关电源线长度(向左出线长/向右出线长)室内/室外机连接电线规格0.65/1.35米截面1.5平方毫米YZW电缆·从室内机组的左或右侧底部角落引出电源线。 警告·每台空调必须配置专用供电线路,且供电电源应符合国家标准的规定,并装有独立的电源开关。·禁止割断电源线并连接到其他线路,可能会引起火灾。多余长度的电源线勿束成一团,而应如下图所示收藏妥当。2-1 固定安装板·寻找墙上的结构部分(如柱子等),请一定将安装板固定水??平,如果室内机倾斜将会产生机组滴水弄湿,污损家具物??品等情况。65毫米以上(在左侧和左后侧配管时要有161毫米以上的空间,并要使用衬垫)140毫米以上(距墙壁)水平尺170毫米以上(距墙壁)安装板124×25毫米固定螺丝

2-4 连接室内/室外电线①?打开前面板。②?卸下电气盖的固定螺丝,卸下电气盖。③?把室内外连接电线从室内机组背后穿到前面,接地线连???接至电控盒内侧接地标志处钣金上,再把它固定到连线???端子台上。④?将电器盖结实地装在原位,拧上固定螺栓。确认电线塞入端子台内,中心不得暴露在外。为防止安装板的微振动,????位置的孔一定要加以固定。????部分也尽可能?加以固定。·采用埋入水泥墙壁的膨胀螺丝时,应使用45厘米间距的11×20、11×26椭圆孔以固定安装板。如果膨胀螺丝太长时,请改用市场出售的短螺丝。2-2 在墙壁上钻孔①确定墙壁孔的位置。②使用钻头钻一个由内至外稍微向下倾斜的直径65毫米的??孔。③墙孔里插入套筒C。④将腻子H嵌入墙孔与套筒之间。决定壁孔位置100毫米安装板1电气盖固定螺钉室内/室外机组连接电线A 警告插入量尺直径65毫米的孔中心拉直量尺左边的孔也用同法进行搬运机组时,禁止握住机组两边凸出部位。21

安装说明 警告·室内外机组之间的配线,须使用规定的电线连接妥当并使接线端子不直接受到外力的影响确实固定好。·如果连接或固定不妥,可能引起火灾事故。·电线固定夹电气盖必须确定固定好,如没有装好,则可能因为灰尘、水份进入而引起火灾或触电事故。·注意不能连错线。·如果地线连接错误,有可能导致触电。 注意·旋紧端子螺钉以防松脱。·旋紧螺钉后,轻轻拉动电线确认是否能拉动。·如果接线不正确连接到端子盒,空调机就不会正常运转。 警告·室内外接线端子台之间的连接电线必须按标注号码 一一对应连接。室内接线端子台S1S2S32-5 自动重新启动功能使用遥控器控製空调机时,室内电控基板会记忆运转模式、设定温度以及风扇速度,如果运转时发生断电,自动重新启动功能就会在恢复供电后工作,使空调机自动重新启动,如果空调机在断电前是以“I FEEL CONTROL(体感控製)”模式运转,此模式就会被记忆。在“I FEEL CONTROL(体感控製)”模式下,空调机的运转由(重新)启动时的室内温度决定。如何设定“自动重新启动功能”①卸下前面板。②卸下电气盖的螺钉。拆下电气盖。③从CN151拔下叶片电动机接头。

拆下电气盒内的风叶电动机导线。

从CN111,CN112拔下温度传感器接头。

从CN110拔下动态地面温度传感器接头。④拉出电控基板,切断其上的电阻JR07。运转黑白红黄/绿S1S2S3室外接线端子台①如果切断了主电源,运转设置仍被保留。②恢复供电3分钟后,空调机会根据存储器记忆的内容自动??重新启动。MSZ 型变频型<接线详图>室内接线端子台松开端子螺钉橡套软线4芯MSZ-YK09/12VA-H1端子台导线黑白红MSZ-YK18VA-H1接地线(绿/黄色)室外接线端子台 警告·家中电源插座内火线、零线、接地线必须按如图连接,位置不能接错,并连接可靠,无内部短路。·连接错误,有可能导致火灾。用户家中供电插座示意图接地( )注:·操作遥控器10秒钟之后,运转设置就会被保存。·当启动了自动开机/关机定时器时,如果关闭了主电源或是发生断电,定时器设置就会被取消。由于这些型号都具备自动重新启动功能,一旦恢复供电,3分钟后空调机就会开始运转。·如果在断电前用遥控器关闭了空调机,由于遥控器上的电源键关闭,自动重新启动功能就会不起作用。·为了防止起动电流对电源的冲击,请有序安排其他家用电器开机时间,避免同时开机。2-6 配管作业·一定要将排水软管配置在製冷剂管道的下方。·不要使排水管隆起或盘曲。·不要拉着排水软管进行包扎。·排水软管须通过室内时,一定请用市售的隔热材料缠绕??包扎。·用毛毡胶带5包裹配管、排水软管,并收纳在室内机组??后面的配管收纳部里面。液体管零线(N)火线(L)釘排水软管气体管毛毡胶带22A5

安装说明向后、向右和向下铺设管道管道铺设·管道配置??将製冷剂管道和排水软管汇总在一起,使用包扎带进行缠绕。注意,切勿使排水软管抬高起来。由管道末端开始,使用管道包扎带??牢靠地缠绕。E43将橡胶塞塞入室内机组背面装插排水管的部位用内六角扳手把橡胶塞压入排水盘接口处。排水橡胶塞将排水软管接插到室内机组背面右侧的排水软管接插部位请将排水软管插到排水盘接口处。一定要确认软管是否确实卡住排水盘的突起卡爪。排水软管往右侧配管时切掉此部分。往下侧配管时切掉此部分?。·把管道和排水管插入墙壁孔套管C,并把室内机组的上半部??分挂在安装板1上。·左右移动空调机,检查空调机是否可靠地挂在安装板1上。製冷剂管与延长配管的连接如果在墙中已埋设有延长配管或配线时,即请按照下图所示要领进行配管连接工作。①将室内机组上部钩住安装板1,并考虑到配管的收纳而尽可能向左边靠紧之后,切下一块包装材料(当衬垫用)使卡住背面凸缘,如右图所示抬高室内机组。·把製冷剂管与延长管B连接起来。切下包装材料的一部分(衬垫用)卡住背面凸缘室内机组包装纸板用剪刀或刀具切下纸板。向左或者左后铺设管道·管道配置将製冷剂管道和排水软管汇总在一起,先用管道包扎带进行缠绕,再用毛毡包扎带5进行缠绕。往左侧方向配管时,在注意,切勿使排水软管抬高起来。此切断去掉。毛毡包扎带5(管道包扎带????)E应从管道末端开始缠绕毛毡包5?5?扎带??(毛毡包扎带??重叠部分应为毛毡包扎带宽度的1/3)5应在毛毡包扎带??最终端上,使用胶带固定。使用遮蔽胶带或室内机组下侧所附胶带固定末端。如上图所示卷起切下部分。衬垫排水软管的改装法左、左背后配管时,一定也要把排水管改装过,如果不加改装,可能产生滴露水。如上图所示,一边注意方向,一边将衬垫确实地套进背面凸缘的凹陷部分。室内机组安装板1将卡钩压入在安装板 孔中1室内机组的安装·将管道穿过墙壁,将机组吊装在安装板1上,推入室内机组直到它发出卡嗒一声。2-7 排水管道铺设排水软管排水橡胶塞为了使排水顺畅,应使排水管道形成往下倾斜状态配管。(图1)切勿使排水管道连接形成如图2~图3上所示。切勿抬高

排水滞留 空气1室内机组背面右侧的橡胶塞抓住尖端凸缘部分把橡胶塞拔下来。橡胶塞漏水(图2)排水软管的端部浸入水中下倾距地面5厘米以下(图1)波浪形(图3)(图4)2卸下室内机组背面左侧的排水软管抓住箭头所指捏手部分按方向拔出排水软管。假如装在室内机组上的排水软管,使用时长度还不够,可采F用附件中的排水软管???连接使用。排水软管需通过室内时,一定要使用市场上销售的隔热材料缠绕包扎。排水软管23

安装说明3.室外机组的安装室内/室外连接·将来自室内机组的电线,正确地连接在接线端子台上。·注意禁止使连接导线接触配管。松开端子螺钉4.完成室内/室外机组连接以及进行试行运转4-1 管道连接①室内机组接管??连接液,气配管至室内机组。·首先对准中心,然后用手旋上管螺母至无法转动。·参考下面扭矩表,使用两只扳手拧紧室内机组侧接管接头部分。请注意勿过度扭紧,以免损坏扩口部分。管径毫米6.359.5212.7旋紧扭矩端子台导线·厘米(kgf·英寸牛顿·米(N·m)公斤力cm)13.7到17.7140到1801/434.3到41.2350到4203/849.0到56.4500到5751/2 注意·注意不能连错线。如果接线不正确,空调机就不会正常 运转。·旋紧端子螺钉以防松脱。·旋紧螺钉后,轻轻拉动电线确认是否能拉动。②室外机组接管与室内机组相同方法把配管接到室外机组的截止阀(2通和3通阀)管接头。·使用扭矩扳手或普通扳手,用和室内机组同样的扭矩旋紧。 警告装机时,在启动压缩机前,确保管子安全的连接。一定请用此导线夹将室内外连接电线A固定好。隔热及缠绕包扎带A①室外机组侧的各配管及阀都须作隔热处理。②从室外机组的配管入口起的全部配管都须用管道包扎带??E缠绕包裹。·用胶带固定管道包扎带E的末端。·如果配管通过天花板,盥洗间或其他高温高湿的地方时,??请加包裹以市售隔热绝缘材料,以防凝露。4-2 抽真空·泄漏试验?固定螺丝抽真空过程连接室内机组与室外机组之间製冷剂管道(液体及气体管道)。卸下室外机组气体管道侧的截止阀的维修口盖(不卸下盖子无法进行抽真空过程。) 注意确实固定好室外机组的维修板。维修板如果没固定好,将因为灰尘、水份等进入而引起火灾、触电事故。利用真空泵将维修用压力表和真空泵连接到室外机组气体管道侧上面的截止阀的维修口上。转动真空泵(抽真空达15分钟以上)。用维修用压力表检查真空,然后关闭维修用压力表,并停掉真空泵。 注意·空调器的安装面应坚固结实,具有足够的承载能力,其承载能力不低于实际所承载的重量(至少200kg/m2)·安装面为木质、金属或非金属等结构,如果其强度明显不足时,应采用相应的加固、支撑和减震等措施。·安装架必须使用能使空调器可靠地固定在安装面上的紧固件。·安装时使用的紧固体,应根据安装面材质坚硬程度确定安装孔直径和深度,并选择适用的膨胀螺栓规格,确保安装空调器稳定、牢固、可靠。·安装时避开雨天、风雪天、雷雨天进行安装,必要时采取相应措施保证自身和他人不受伤害。维修用压力表截止阀液体管道六角扳手气体管道盖子连接管道截止阀维修口真空泵迅速地从截止阀的维修口卸下维修用压力表全开气体和液体管道侧的所有截止阀,若不全开截止阀运转,将降低机器性能或引起故障等。管道长度在限定范围内,无须补充製冷剂。旋紧维修口盖再旋紧两个截止阀盖泄漏试验管道长度超过一定范围,补充定量製冷剂。24

安装说明紧固力矩牛顿·米维修盖截止阀盖13.7到17.719.6到29.4公斤力·厘米140到180200到3005-2 卸下室内机组从安装板上拉出室内机组的底部松脱两角按下图所示,把室内机组的左右下角往下和往前拉,松开锁钩。4-3 试运行运转MSZ型变频型·在进行运行之前,应再次检查是否有错误的接线。??错误的接线会妨碍正常的操作,或熔断保险丝而不能起作用。·可用应急开关开始试运转。按下应急开关,机器即根据所选模式开始连续製冷或製热运转30分钟。在此30分钟内,恒温器不起作用。30分钟后,机器将开始以24℃的固定设定温度进行製冷模式或製热模式的应急运转。·按下列程序进行试运行。程 序如果不能采用上述方法时如果不能采用上述的方法,即请卸下前框并如下图所示将六角扳手插入左和右边方孔中,然后将六角扳手往上推。室内机组底部被压下,挂钩即被释放。推·按下应急开关。??①按一次开关即试运行30分钟后应急製冷模式启动。??②再按一次即开始应急製热运转。??③再按一次即停止运转。????每次按下应急开关即将作①→②→③的反复。压下方孔5-3 补充製冷剂运转模式操作指示灯测温测温测温应急製冷应急製热停止?①将储气瓶接在截止阀(3路)的维修口。?②用来自储气瓶的製冷剂进行管道(或软管)的气洗。?③在空调机以製冷状态运行时,补充指定量的製冷剂。 注意事项·补充时,请勿倒转储气瓶灌製冷剂,否则,可能发生问题。连接器室内机组6.35截止阀室外机组注意:·这是应急运转模式的指示,在应急运转期间测温方向的??设置无效。製冷剂储气罐操作阀製冷剂储气罐9.5212.7(YK18-H1)维修口确认接收到遥控器的信号按了遥控器的运转/停止按钮后,请确认室内机组的本机上是否发出嘟!声。然后再按一次按钮以关掉机器。用遥控器控製时,遥控器指令运转后,应急运转都将被解除。充气软管弹簧秤(R410A气体)充气·为了保护压缩机,空调器停止后3分钟内即使重新开机,室外机也不会被启动。4-4 应对用户说明的事项·请按照使用说明书,向客户介绍有关温度调节控製的方法,空气过滤网的拆卸、左右导风板组件的拆卸方法、清扫方法、及在操作使用时的注意事项等。5.安装后的迁移安装和维修为使储气瓶保持高压,在寒冷季节时,请用温水(40℃)加热。但禁止使用火烤或用热蒸气蒸热。注:①室内接线图贴在室内机组前框内侧。 ②室外接线图贴在室外机组电控盒。5-1 如何安装前框?①在安装前框以前,请将上下导风板设定于3号(第10页)???位置。?②在上下导风板下方插入前框底边。?③固定好前框顶部。?④按下前框上搭扣,将前框固定于空调器上。25

安装说明5-4 如何回收製冷剂 在对室内机和室外机实施移机及废弃的场合,出于环境 保护考虑,请勿将製冷剂排放到大气中,请按如下步骤 实施製冷剂回收。①切断电源(断路器)。②将维修用压力表的低压阀连接到室外机气体侧截止阀 的维修口。③将室外机的液体侧截止阀全闭。④打开电源(断路器)。⑤实施製冷剂回收(製冷模式试运行)运转。试运行方法按一下室内机组的应急运转按钮,实施製冷模式试运行。⑥当维修用压力表的压力达到0.05~0MPa〔表压〕(约 0.5~0kgf/cm?)时,将气体侧截止阀全闭,迅速让空 调停止运行。停止方法按室内机组的应急运转按钮,停止试运行,使空调机停止运转(具体请参照第25页中试运行运转的说明)。注意:当维修压力表的压力达到0.05~0MPa〔表压〕时, 请在3分30秒之内全闭气体侧截止阀并迅速停止空 调运行。如不及时全闭气体侧截止阀并迅速停止空 调运行的话,将因出现保护停机而无法完成製冷剂 回收。⑦※在连接配管很长、製冷剂充注量很多的场合,有可 能无法实施製冷剂回收。 在这种场合,请用製冷剂回收机来回收系统内的全部 製冷剂。⑧切断电源(断电器)后,拆下维修用压力表,拆除室 内、外连接配管。製冷剂回收作业时,连接配管拆除前必须停止压缩机。警告压缩机运行状态下,如在截止阀(球阀)开启状态下拆除连接配管,会吸入空气,导致冷冻回路产生异常高压,从而引起破裂及受伤事故。26

Safety precautions·Please read this [safety precautions] before use.·The precautions mentioned here are about very important contents for safety, which should be s used in text :Forbidden. :Be sure to do following instructions. :Inserting fingers or sticks is not allowed. :Stepping or piling on the indoor/outdoor unit is not allowed.?:Risk of electric shock, take care.?:Be sure to remove the power plug.

?:Be sure to turn off the power suppply.?:Must be grounded.·Please keep the manual in a place which is accessible for reference after reading.·Young children or weak people must be supervised to use the air conditioner. WarningDon\'t connect wires in the middle section of a power cord or extend the cord and use multi-cable socket.·Fire or electric shock may result from poor contact, poor insulation and ’t damage the power cord or use it for connecting or processing.·Piling on the power cord and damaging or heating/connecting/processing the power cord may damage the cord to cause fire or

electric shock..Don\'t remvoe the power plug in operation.·Sparkle may occur to cause fire.·After turning off the indoor unit by a remote controller, be sure to switch off the protection switch or securely remove the power plug.

Don\'t let the cold airflow blow the skin directly for a long time.·May do harm to health.

Don\'t install the machine by yourself.·Improper installation may cause fire, electric shock, water leakage or injury from machine falling. Please contact the specialty shop or

technical service center for \'t use the air conditioner in an environment to place or use volatile, corrosive and combustible chemicals.

·Don’t use the air conditioner when volatile, corrosive and combustible chemical products(such as xylene, isoamyl acetate and

methanol) are used in room.·Doors and windows should be opened for ventilation if the paint in decorated room is not dried. The air conditioner can’t be used until the gas from

thinner evacuates. Otherwise, corrosion, deformation and even fire may \'t put a combustion apparatus in a place directly facing the airflow outlet.·Incomplete combustion for combustion apparatus may \'t spray directly with pesticide, disinfector and combustible spraying material.·Fire and distortion may the installation stand is antiquated, don\'t ignore it.·The unit may tumble and cause ng on an unstable footstool is not allowed in case of unit maintenance.·Fall and injury may \'t pull the power cord.·Hold the plug and pull it out while removing the power cord. Otherwise, fire may result from partial disconnection of the power cord ing fingers or sticks in the inlet and outlet is not indoor installation height should ensure that the fan is at least 2.5m

above the ground.·Injury may result from inside high-speed fan.·Young children must be supervised to ensure that they don\'t play with the air case of abnormity(a burnt taste), stop operation at once, pull out the plug and switch off power supply.

·Keeping on operation in case of abnormity may lead to fire and failure. Please contact the specialty shop or technical service center for help.

Remove the dust on the power plug and make a stable insertion.·Fire or electric shock may result from the plug with dust or poor using the air conditioner together with a combustion apparatus, you shall ventilate the room frequently.·Insufficient oxygen may the power plug in case of long term out-of-service.·Fire and accident may result from dust ng or piling on the indoor/outdoor unit is not allowed.·May fall down to be injured or get injured due to unit \'t try to repair the unit by yourself or remove the unit.·Maloperation may cause fire, electric shock, water leakage or injury from unit fall. Please contactthe

specialty shop or technical service center for help.·If a power cord is damaged, the manufacturer or service provider shall replace it to avoid loss.27

Safety precautions NoteWhen removing the filter, you shall take care not to touch the metallic part of the indoor unit.·Probability of being \'t put animals and plants in a place directly facing the airflow outlet of the air conditioner.·May have bad impact on the animals and \'t charge or remove the battery, and don’t put it in fire.·May cause battery leakage, fire or \'t open doors and windows and let the air conditioner operate in high humidity for long period.·In cooling mode, if the air conditioner operate in high humidity(over 80%) for long period, condensed water may drop from the unit, wet and contaminate \'t use the air conditioner for other applications.·The air conditioner is not used to preserve precise apparatus, food, animals and plants and artwork due to probability of lowering their cleaning the air conditioner, you shall stop operation and remove the plug or turn off the power supply.·High-speed revolving fan may cause injury in two new batteries of the same type.·Combination of new and old batteries can cause heating, leakage or the battery fluid splashes against the skin or clothes, please clean them carefully with clear water.

·If the battery fluid splashes into the eyes, wash the them immediately and see a \'t operate a switch by a wet hand.·Risk of electric \'t wash the air conditioner with water.·If there is water inside the unit, the insulation feature will be lowered and electric shock may result.

Installation of air conditioner Warning·At the time of installing a machine, please contact the specialty shop or technical service center for help.

NoteDon\'t install the unit in a place where corrosive and combustible gases may leak.·There is a risk of explosion or machine damage in case of gas leakage or gas deposit around the \'t pile up other electric appliances or furniture under the indoor/outdoor unit.·Contamination or device failure may result from drips from the be grounded.·The socket for air conditioner should be connected with special earth wire. The earth wire shall not be connected to gas pipe, tap water pipe, lightning rod or telephone earth wire. Electric shock may result in case of no earth wire or poor grounding. Thus, before using the unit, you have to confirm whether there is an earth wire or grounding connection as leakage circuit breakers must be installed in some installation fields (such as place with high humidity).

·If an earth leakage circuit breaker is not installed, an electric shock may result.

Make sure to have a smooth draining at the draining port.

·If the draining is in poor condition, the unit may wet and contaminate the furniture.28

Part nameIndoor unit主机Front panelHeat exchangerAir inletHorizontal vaneVertical vaneAir outletDisplay sectionFilterDisplay sectionAREA lampOperation lampEmergency operation switchMOVE EYE sensorRemote controller receiverOutdoor unitAir inlet

(back·side)Piping

Drainage hoseAir outletDrain outlet29

Preparation before operationRemote controllerSignal transmitting sectionHow to install battery and set current time1Remove the frontal cover and install batteries.

Then, reinstall the cover. Insert the cathode of the batteries in

the first. Check if the polarity is ion display sectionOperate/stop(ON/OFF) buttonFan speed control buttonOperation select buttonEcono Cool buttonSleep control buttonTemperature buttonFirst, insert the negative electrodeVane control button(Horizontal vane button)OFF-TIMER buttonON-TIMER buttonTime setting buttonForward buttonBackward buttonClock setting buttonReset button2Press the reset sharp thing to press it.·If the reset button is not pressed, the remote controller can’t

work normally.·Note that the pressing shall not be done something sharp at the end to press it.3Press the Clock setting button.4PressMOVE EYE buttonWide vane button(Vertical vane button)Area setting button(forward) and(backward) button (time

setting button), set current time.·Each press of the Forward button increases one minute; Each press of the Backward button decreases one minute.

·If you press and hold down the button for a long time, the set time will increase/decrease in ten minutes intervals.

5Repress the Clock setting button and close the frontal TO SWITCH OVER The details of SLIDE SWITCH①Remove the front lid.②Be sure to set the slide switch inside the remote controller to an

appropriate position in accordance with the installed position of the

indoor unit. If the switch is not set correctly, the air conditioner may

not function AreaPosition of the slide

switchLeftCenterRightDisplay on the

remote controllerWhere is the indoor unit installed in the room?Installed at left, if the distance

is not more than 50cm.(Left)(Center)Installed at right, if the distance is

not more than 50cm.(Right)* If the indoor unit is installed more than 50 cm away from the side walls,

cabinets or other nearby objects, set the slide switch to the \"center\" position.30

Preparation before operationHow to use the remote controller·The signal can travel up to 6 meters (in a straight line)away from

the frontal face of indoor unit.·At the time of pressing the button, the indoor unit beeps once

or twice to confirm the signal received. If the unit doesn’t beep,

press the button again.·Use the remote controller it falls down to the ground, is thrown or soaked in water,

malfunction may y■Standard for replacing battery

Two new alkaline batteries (No.7, LR03) shall be replaced in

the following condition:·The indoor unit has no response to the signal sent from the

remote controller.·The display of the remote controller becomes don\'t use manganese battery, or the remote controller

will be in failure.·The lifespan of a alkaline battery is about one year. However,

it\'s recommended to consider the expiration date (year/month)

at the bottom of a battery. If the expiration date draws near, the

battery should be replaced as soon as possible.·In order to avoid fluid leakage, please take out the battery if it

is not used for a long the battery fluid splashes against skin or clothes, please wash

Note:them with clear water the battery fluid splashes into eyes, please wash them with

clear water immediately and see a doctor.·Don\'t use rechargeable battery.

·Two batteries shall be of the same type.·Obsolete batteries shall be disposed of -restart function■The unit is set with auto-restart function, which is set to OFF when

the unit leaves factory. If you want to use the function, contact the

technical service center.

Auto-restart function refers to

the following contents:...When the indoor unit is controlled by the remote controller,

the unit will automatically remember the operation mode, set

temperature and fan speed. If power cut or power-off occurs

during operation, Auto-restart function will enable the unit to

start automatically and operate in the previous mode set by the

remote controller after power-on.

Indoor unitInsert the power plug in the socket. Turn the power switch

to ON m a firm connection by removing the dust on the power plug.

WarningFire or electric shock may result from a plug with dust or socket in

the remote controller can\'t be used

(emergency operation)When the dry batteries in the remote controller are exhausted, or when

the remote controller is in failure, you can use the emergency operation

button on the unit to control the operation.1Press the emergency operation button.·Each press of the button enables the unit to change operation

mode following the order of Cooling→Heating→·The operation mode is indicated by the AREA lamp on the indoor

unit as follows:Operation mode

AREA lampEmergency cooling

AREAEmergency heating

AREAStopAREANOTE:·In emergency operation, AREA setting is not work.·The operation is described as the first 30 minutes, the unit only operates continuously without

impact from room temperature. The fan speed is constant. After

30-minute operation, the unit status is as follows:Operation modeCoolingHeatingSet temperature24℃ 24℃

Fan speedMediumMediumHorizontal (vane)

Automatic Automatic

Vertical vane

Front Front

2·To stop the Emergency operation, press the Emergency

operation press of the button enables the unit to change operation

mode following the order of Cooling →Heating →Stop.31

\"\" Auto OperationIn the mode of \"\" Auto Operation, one press of the button enables the room condition to reach optimum starting \"\" Auto Operation■Press button.

At the time of displaying (Auto Operation), the air conditioner is automatically controlled to the optimum temperature.

When stopping

■Press buttonAbout 15 minutes after the start of operation:If you feel too hot:■Press button to decrease the temperature.

Each press of the button decreases the temperature by about 1℃If you feel too cold:■Press button to increase the temperature.

Each press of the button increases the temperature by about 1℃.At the time of not displaying (Auto Operation), please press button to set Auto Operation press of the button enables the unit to change operation mode following the order of (Auto Operation) →

(Dry)→ (Heating)→(Fan). (Cooling) →

Auto Operation modeAuto OperationThe operation mode is automatically set to Cooling, Dry or heating based on the room temperature at initial operation. However, if the unit

operates again within 2 hours after stopping, it will operate following the same set points with the previous operation. Once the set points are set,

the operation will not vary with the room temperature. If you don’t like the set points, you can press button, then select proper set points for \"\" Auto OperationRoom temperature at initial operationOver 25℃ Below 25℃Below 23℃Operation modeCooling

DryHeatingTarget temperature (initial status)About 24℃-About 26℃Note:Cooling: When the room temperature is 2℃ higher than the set temperature, the latter will not change. Because the air conditioner is operating

to reach the target (set point) temperature. Meanwhile, please wait for room temperature to decrease to the temperature around the set one

(+2℃) , then you can change the set temperature.

Heating: When the room temperature is 2℃ lower than the set temperature, the latter will not change. Because the air conditioner is operating

to reach the target (set point) temperature. Meanwhile, please wait for room temperature to increase to the temperature around the set one

(+2℃) , then you can change the set temperature.

32

Manual operation (Cooling,Dry,Heating,Fan)When selecting operation mode (Cooling, dry, heating, Fan)1Press button.2Press button to select operation press of the button enables the unit to change operation mode following the order of (Auto Operation) → (Cooling) → (Dry)→

(Heating)→(Fan).When stopping

■Press button. button, the air conditioner will operate following the set the operation mode. Once you press

■When changing set temperature:

·At the time of decreasing temperature, press

·At the time of increasing temperature, press

button. Each press of the button decreases about 1℃.

button. Each press of the button increases about 1℃.When operating in Dry mode·Unable to control temperature (temperature setup)·Operate at the temperature slightly lower than room :·When the environmental temperature is too high, room temperature may not reach the set temperature due to excessive load in cooling

operation.·Heating principle for heat pump type air conditioner: The unit absorbs heat from outdoor air by refrigerant cycling, transmit the heat inside

the room and heat up the air in the room. The heating capacity decreases with the temperature drop of outdoor temperature.·If outdoor temperature becomes extremely low, please use the unit together with other heating for using air conditionerCooling:how to make an efficient cooling operation1. Close the windows tightly, put down the curtain, and reduce sunshine amount.2. Stick commercially available heat shielding film to the windows for reduction of sunshine heat.3. The outdoor unit shall be installed in a place where the sunshine is warmth beneficial to health mainly depends on the temperature difference between indoor and outdoor environment!The set temperature for heating operation shall not differ from outdoor temperature excessively. Although it varies with the region,

generally speaking, the set temperature can be set to 20℃~24℃.A humidity of 70% is a divergence point at which people feel people feel sultry, it indicates that there is a great number of vapor in the air, that is to say, the humidity is high. Humidity

is concerned with temperature and airflow. Generally speaking, a humidity of 60%~75% in summer and that of 55%~70% in

winter shall be the ideal condition at which people feel most comfortable.

Heating:Dry:33

MOVE EYE Sensible temperature

The proceed of the unit’s temperature control is a gerneral temperature control proceed, that accord to the temperature of wall,

floor and room measured by MOVE EYE sensors (MOVE EYE control operation).When cancel MOVE EYE control, the gerneral temperature control proceed will ng MOVE EYE controlMOVE EYE control operation is activated when MOVE EYE button is pressed with a thin stick in manual COOL or manual HEAT :MOVE EYE control operation is activated when the remote controller is first used following replacement of the batteries or resetting of the remote

ling MOVE EYE controlMOVE EYE control operation is canceelled when MOVE EYE button is pressed with a thin stick once :If the conditioner is turned OFF without cancelling MOVE EYE control operation, MOVE EYE control operation is activated the next time the air

conditioner is turned EYE control operationThe sensors constantly measure the room and floor/wall tempera-tures to automatically adjust to the set temperature by estimating

the temperature actually perceived by a person inside the room

(\"sensible temperature\").Advantages:The air inside the room is conditioned quickly to a comfortable

room will not become too cold or hot even when the air

conditioner is kept on for a long mperatureWalltemperatureHumidityApprox 20%FloortemperatureApprox 50%SensibletemperatureAdvantages of i-seeApprox 30%Wall/floor temperatureRoom/air temperatureMOVE EYE sensorWhen AREA setting is not activated, the sensing range of MOVE EYE Sensor differs depending on the installation location of the lation

opsitionInstallation at leftInstallation at centerInstallation at rightImage of sensing

rangeApprox 150 degreesDriection of sensorLeftCenterRightRefer to the description for slide switch setting. (Page 30)Install the front panel correctly after being removed for maintenance or service so that the floor/wall temperatures can be measured correctly.34

AREA SETTING

When AREA have been setted, horizontal air flow (Horizontal Vane) can adjust automatically according to the temperature measure

from the wall and setting·Press AREA button.·Each time the button is pressed, the area is changed in sequence: (AUTO)

→ (LEFT)→ (RIGHT)→CancelMOVE EYE Sensor moves intermittenly, measuring the floor and wall 1: AREA setting is only available during MOVE EYE control operation. (Refer to page 34)NOTE 2: If AREA setting is canceled, the vertical vane returns to the previously set position before AREA 3: The horizontal air flow direction (WIDE VANE button), including horizontal SWING, can not be set during AREA setting.·If AREA setting is set to AUTO in heating operation, the indoor unit automatically delivers warm air to the area where the

Moving

of

horizontal

air

flow

directionfloor/wall temperature is the lowest in the room.·If AREA setting is set to AUTO in cooling operation, the indoor unit automatically delivers cool air to the area where the

floor/wall temperature is the highest in the .) In heating operationDayWarm areaNightCold areaThe indoor unit delivers warm air detecting the cold area in the

unit

displayNOTEIndication of AREA setting·The horizontal air flow direction changes if MOVE EYE Sensor detects approx.3 temperature difference.·In AUTO of AREA setting, both right and left lamps are lighted when the room is evenly lightedLightedCancelling AREA settingAREA setting is cancelled when the “cancel” is sellected by pressing AREA button, or when WIDE VANE button is unit installation location and air-conditioning lation at leftInstallation at centerInstallation at rightLEFTRIGHTLEFTRIGHTLEFTRIGHT·Be sure to set the side switch inside the remote controler to an appropriate position in accordance with the installed position of the

indoor unit. If the switch is not set correctly, the air conditioner may not function properly. (Refer to Page 30)35

AREA SETTINGAREA settingTo air-condition mainly the left area of To air-condition the entire air-condition mainly the right area

the horizontal air flow direction and of the unit display are switched

according to the room temperature

(floor/wall).Press AREA button to select LEFTPress AREA button to select AUTOPress AREA button to select RIGHTRemote controller buttonControl

range of

Installed at

horizontal

centerair flow

direction.

The vertical

air flow

direction

conforms

Installed at

to the

leftsetting on

the remote

controller

(The

horizontal

air flow

direction is

Installed at

controlled

rightin this

range.)Indoor unit

displayAREAAREAAREAAREAAir flow velocity and direction adjustmentSelect your favorable fan speed and airflow direction■To change the airflow velocity, press the button. (Lo)→(Me)→(Hi)→(SHi)→(Auto).How to select fan speed:Principle of the air conditioner: The greater the air volume, the more effective the energy saving, and the higher the noise. The air

outlet temperature increases at cooling mode and decreases at heating mode. Therefore, selecting the fan speed of Lo enables

you to get a quiet environment for rest. Selecting the fan speed of Hi or SHi enables you to get an effective energy saving.■At the time of changing vertical airflow direction, press

Each press of the button enables the unit to change vertical airflow direction following the order of (1)→(2)→(3)→(4)→(swing)

→(auto).

Air flow with swing

Swing operation enables the airflow to reach all corners of a room. ended scope for vertical airflow directionUsually, please turn to (auto).Turn to position (1) in cooling or dry mode.

Turn to position (2) ~ (4) in heating mode.

CoolingDryHeating36

Air flow velocity and direction adjustmentMovement of horizontal vane

Cooling/ DryStart of heating①①①HeatingAUTOHorizontal position①①Horizontal

positionWhen the air is

Horizontal

position④④④Position 4·The vane moves to the horizontal position after stopping :

The airflow is higher than position 1.·After the air conditioner starts to operate, the vane stops in horizontal position.

④④Once the temperature of the airflow from indoor unit is enough high, the vane

will move to Set position 4.·Once the air conditioner starts to operate, fan speed increases with the

temperature rise of airflow from the indoor unit and until the set of heating②②②③②③③③④①④④④②①1/2 or one①①hour later①②②②②ManualHorizontal positionWhen the air is

Set positionPosition (1) or (2)②②③③④④·After the air conditioner starts to operate, the vane stops in horizontal position.

The airflow direction is set to position (2) , (3) or (4)Once the temperature of the airflow from indoor unit is enough high, the vane will

·When the air conditioner operates for about one hour, the vane

move to Set to position (1) or (2) automatically. Press the button

·Once the air conditioner starts to operate, fan speed increases with the temperature

Vane on the remote controller to change the airflow direction

rise of airflow from the indoor unit and until the set to original set point.

·The vane moves intermittently between position (1) and (4). The

·The vane moves intermittently between position (2) and (4). The vane stays at

position (2) and (4) for a stays at position (1) and (4) for a ②②②①②④②④④④④④Note:

·To adjust the airflow direction by the air conditioner. Moving the vertical vane or horizontal vane by hand may cause failure.·When the operation mode changes to mode \"(auto)\", the horizontal vane changes to different positions automatically mentioned above.

■Press button to change airflow direction (left/right).

Each press of the button enables the unit to change the vertical vane angle following the order of

(Swing)Blow with with swing enables the airflow to reach each corner of the room.37

Sleep OperationIf you want to sleep, please select the function in Cooling selecting Sleep mode1Press button when the unit is operating.

Fan speed is changed to Auto. Changing fan speed enables you to quit Sleep mode.

2Press button or button to set a temperature in Sleep mode.

After setting of the temperature in Sleep mode, press button again to show the temperature set in previous quitting Sleep mode3Press button mode can be quitted by pressing button or changing operation mode can be used together with TIMER ON/ mode descriptionAt the time of pressing button, the display darkens, fan speed is changed to Auto mode automatically, and the air conditioner

operates with low noise.

·When the air conditioner operates in Sleep mode, cooling or heating capacity is not enough, thus, you can quit Sleep g/Heating mode■The air conditioner operates at the temperature set prior to pressing Sleep mode button, about 30 minutes later, the temperature is changed to that set in Sleep mode.

Change of the set temperatureSet temperature in Sleep modeIn Cooling mode, it is suggested that you’d better set a

temperature 1℃~2℃ higher than current temperature to

avoid catching a cold in sleep; In Heating mode, 5℃~6℃

lower than current temperature to make a sound temperature set prior to pressing

button (about 30 minutes)Set temperature in

Sleep modePress buttonIf ON-Timer is enabled to activate Sleep mode, the air conditioner will operate at the temperature set in Sleep temperature for ON-TimerInitial set temperature for the remote controllerIf the remote controller is reset after change of batter-ies, the setting for initial temperature is as follows:Sleep mode (cooling): 28℃Sleep mode (heating): 17℃Set temperature in

Sleep modeON-Timer combines with Sleep mode38

Econo Cool operation

Enable this mode to enjoy healthy, comfortable and power-saving cooling operation.

Please operate as follows in manual cooling modePrees the air conditioner operating in (Econo Cool) control mode, which controls the horizontal vane to swing periodically and automatically

according to the outlet temperature.

Moreover, the set temperature increases by 2℃ automatically based on cooling quitting Econo Cool operationPress button again.·In Econo Cool operation, press button or change operation mode to quit Econo Cool button, or button and Timing ON/OFF button can be used further.

·Airflow speed button, Extreme Hot or Extreme Cold button and Timing ON/OFF button can be used is Econo Cool?Swinging airflow (variable flow) feels cooler than constant airflow, therefore, even if the set temperature is set to a higher one

by 2℃ you can feel comfortable and power is saved.

Timer operation (ON-Timer and OFF-Timer)You can preset the air conditioner to ON-Timer and OFF -Timer at the time of sleeping, going home or getting to set ON-Timer1Press button.

\", the figure to set OFF-Timeer1Press button.\", the figure flashes.2Press ON-Timer button \"Set time for the timer by pressing Time button (increase) and

(decrease).Each press of button increases the set time in 10 minutes intervals

and each press of button decreases the set time in 10 minutes

intervals.2Press OFF-Timer button \"Set time for the timer by pressing Time button (increase) and

(decrease).Each press of button increases the set time in 10 minutes intervals

and each press of button decreases the set time in 10 minutes

ON-TimerPress OFF-TimerPress OFF-Timer button \"\".Combination of ON-Timer

and OFF-TimerCombine ON-Timer with OFF -Timer. The unit will operate first at the

earlier set time.

(The mark \"↑↓\" shows operation order of timer.)

·If the current time is not set, timer operation will be :If main power supply is switched off or power failure occurs during

timer operation, timer setting will be canceled.

39

When the air conditioner is not used for a long timeNot used for a long time1Enable the fan to run for 3~4 hours so as to dry the inside

of the air conditioner.·Before fan operation, set to Cooling operation mode and select

highest set temperature..To be used again123Clean the filter and return it to the unit.(Refer to page 41)Be sure to confirm whether the air inlets and air outlets of

indoor and outdoor units are covered.

Confirm whether the earth wire is connected firmly.2Switch off the power supply and remove the power plug.

Warning

Be sure to remove the power plug when the air conditioner is not used

for a long may result from possible dust be earth wire should not be connected to gas pipe, tap water pipe, lightning

rod and telephone you don’t connect the earth wire as required, electric shock may result.

Warning3Take out the batteries in the remote the remote controller is not used for a long time, be sure to take

out all batteries in the remote controller to avoid fluid leakage. Note:MaintenanceBefore cleaning1Switch off the power supply and remove the power plug. Warning

When cleaning the unit, you have to stop unit operation by removing

the power plug and switch off the power supply. Because fan blades in

high-speed rotation may hurt ng for indoor unitClean with soft dry cloth·If there is distinct smear, use a piece of cloth soaked with neutral

detergent to clean the unit.·Never use gasoline, volatile oil, friction powder or disinfectant. Otherwise,

they may damage the unit.·The front panel may fall down after being lifted over horizontal position.

If it falls down, refer to Step 3 in Cleaning for Front Panel.

Front panel cleaning1Press and loose the clips at both ends of the front panel, lift

the panel until you hear a click (1). Hold the hinge, take up

the front panel horizontally, pull out the hinge forward and

remove the panel (2).2Use a piece of soft and dry cloth to clean the panel or wash

it with washing with water, use a piece of soft and dry cloth to remove

water on the panel.·If the panel is too dirty, use a piece of cloth soaked with warm

solution of neutral detergent to clean the front panel.·Don’t clean the panel with gasoline, volatile oil, mixed solvent,

friction powder or disinfectant, and with brush or hard sponge.·Don’t place the panel in hot water, direct sunshine and let it face a

heater for a long time(over two hours). Otherwise, the front panel

will be discolored and distorted.3

Warning

·Don’t pull out the front panel forcibly and drop it, or the front panel

will be both ends of the front panel with hands, place the

panel horizontally, then put the hinge in the groove at the

top of the indoor unit until you hear a click. After that, close

the front panel, press the three positions shown as follows

with hands.·At the time of removing/installing the front panel, don’t stand on unstable

support, or you may be injured.40

Filter CleaningFilter Cleaning (Cleaning is done once two weeks)1Pull out the filter slightly.①?Open the front pand,switch the hooks高效过滤网空气过滤网②?Remove the fitterHooks③Remove PM2.5 Electrostatic Filter Acrossing the gap of Air Filter,Remove PM2.5 Electrostatic Filter by 缺口手指通过空气过滤网上的缺口捏住高效过滤网,按箭头方向抽出。NoteDuring disassembly of the filter, take care not to touch the

metallic part of the indoor unit, as you may be scratched.本品可用吸尘器清理234 本品为一次性产品·不可水洗,清洗空气过滤网时,一定要取下高效过滤网。 Don’t clean the filter with brush or hard sponge, otherwise, the filter will be distorted.·更换年限约2年半(以北京地区为例),由于各地区空气 If the filter is too dirty, use warm solution mixed with neutral detergent to wash the deodorizing filter. 质量不同会有差异。 Don’t use hot water (about over 50℃) to wash the filter to avoid distortion. 根据使用房间的环境可能会缩短使用寿命,特别是附着了 香烟烟油和厨房油污等情况下请及时更换。·高效过滤网型号:S-MAC-621YK。After washing with water, the filter can’t be used until it is a cleaner to clean or use water to wash.

Don’t dry the filter under sunshine or with fire.。Installing the filter.① Install the PM2.5 Electrostatic FilterInstall PM2.5 Electrostatic Filter into Air Filterby the 2.5 Electrostatic Filter mustbe limited by the hook of Air Filter高效过滤网Hooks卡钩PM2.5 Electrostatic Filter高效过滤网空气过滤网②?Replace the filter空气过滤网③?Switch the hooks,stabilize the filter缺口手指通过空气过滤网上的缺口捏住高效过滤网,按箭头手指通过空气过滤网上的缺方向抽出。Hooks口捏住高效过滤网,按箭头方向抽出。5KeepingThe dirt could be removed by the vacuum cleaner.本品可用吸尘器清理PM2.5 Electrostatic Filter is disposable `t 2.5 Electrostatic Filter must be removed before

本品可用吸尘器清理 本品为一次性产品cleaning Air Fliter.·不可水洗,清洗空气过滤网时,一定要取下高效过滤网。Replacement frequency is about 2 years(example of Beijing).According

本品为一次性产品·更换年限约2年半(以北京地区为例),由于各地区空气to the air quality,the replacement frequency would be different.· 质量不同会有差异。不可水洗,清洗空气过滤网时,一定要取下高效过滤网。The product life could be shorten in duty room condition,please replace

·更换年限约2年半(以北京地区为例),由于各地区空气 根据使用房间的环境可能会缩短使用寿命,特别是附着了PM2.5 Electrostatic Filter in time especially in the space which filled with 质量不同会有差异。 香烟烟油和厨房油污等情况下请及时更换。tobacco tar and cooking fumes. 根据使用房间的环境可能会缩短使用寿命,特别是附着了·高效过滤网型号:S-MAC-621YK。 香烟烟油和厨房油污等情况下请及时更换。·高效过滤网型号:S-MAC-621YK。41

Please check the following items before connecting a servicemanIs there a failure?The air conditioner

can\'t pointIs there a failure?Check point·Is the power supply turned on?·Is the fuse blown?·Is ON-Timer set?The horizontal vane

can\'t operate.·Are the horizontal vane and

vertical vane installed in the

indoor unit correctly?·Is the protective screening of the

fan distorted?The indoor unit gives

·Is the filter clean?off remote controller

·Are batteries exhausted?has no message to

·Is the polarity of a battery placed

display or darkens.

correctly?The indoor unit has

·Are buttons on the remote controller

no response to the

of other electric appliance

signal from the remote

pressed? the air conditioner can\'t still operate after the above items have been

checked, please stop using the machine and contact the specialty shop or

technical service center for cooling is not

enough.·Is the temperature setting

correct?·Is the filter clean?·Is the air inlet or air outlet of the

indoor or outdoor unit covered?·Are the doors and windows in

room opened?Please pay attention to the following condition before

asking a serviceman for repair.·In a room decorated with electronic fluorescent lamp, the

signal from the remote controller may be unacceptable.·In circumstances with weak radio wave, the air conditioner

may disturb the signal acceptance of broadcast or TV, thus,

the affected equipment may need a magnifier.·When thunder appears, you have to stop operation and

remove power plug or turn off the power supply. Otherwise,

there is a risk of damaging the electrical part in the air

you think trouble occursIs there a failure?Answer (it\'s normal)Is there a failure?Answer (it\'s normal)The air conditioner

·In accordance with the microcomputer\'s

can\'t operate within

display, it means the protection of

3 minutes after you

the air conditioner, please t the machine.A crack is is blown out from

·The fog results from quick condensation

the indoor unit outlet

between moisture in the air and cold

during w from indoor unit outlet.

Snapping can be

·This is a voice from the switching

heard from indoor

(ON and OFF) of compressor or

fan.

can be heard

·This is a voice in which the air

from indoor ioner starts or stops refrigerant

flowing.

The airflow direction

·When the air conditioner operates

changes during

in cooling mode, if the air is blown

operation. The remote

downwards for one hour, the airflow

controller can’t adjust

direction is set to (1) or (2) automatically,

the movement of the

which is to prevent condensed water

horizontal from dropping.·The noise results from the expansion/shrinkage of the front panel due to

temperature air out of the

·The air conditioner may absorb the

peculiar smells from wall, carpet,

indoor unit has a

furniture and clothes, then mix them

odor air for the Deodorizing filter cleaned?

·Please clean the Deodorizing stops operation

·During dry operation, the unit

uses the same refrigerant circuit

in dry the cooling operation. Dry

operation can\'t decrease the room

temperature in order to reduce the

humidity. Therefore, sometimes the

compressor may stop operation

while indoor unit fan stops running,

which is to prevent the condensed

water drop on heat exchanger from

evaporating similar to

current is is a water

leakage in outdoor

unit.·In cooling operation, pipe or pipe

connector is condensed with water

due to cooling.

·This is a voice from refrigerant

flowing inside the air conditioner.·This is a voice from the flowing of

condensed water drop inside the

heat horizontal vane and

·The condition appears so that normal

vertical vane pauses to

blowing with swing is enabled for the

swing and then starts to

horizontal vane and vertical g in room

·Using exhaust fan or liquefied

can\'t fully meet the cooking utensils can lead to

demand. insufficient cooling with great load.·Extreme high outside air

temperature can lead to poor

cooling similar to air

·This is a voice from the ejection of

water flowing inside the drainage

bubble is when the outdoor air is

absorbed in the hose and when a

soot absorption machine or a vent

fan is activated. If the outside airflow

is strong and blown into the drainage

hose, you can hear the voice too.42

Removal and inspectionCheck and repair■The performance of the air conditioner

decreases due to long-term service and

internal dirt.■Odor may result from using condition, or poor

drainage of condensed water may result from

dust deposit.■The check and repair are different from com-mon ones. You’d better ask for special tech-nical service. Please contact the specialty

shop or technical service center for ion noise should be also

considered.■Don’t place articles at the outlets of outdoor

unit. For the placement will reduce the ef-ficiency and increase noise in operation.■If there is abnormity in operation, please con-tact the specialty shop or technical service

center for you want to remove the

machine■When removing and reinstalling the air

conditioner due to room enlargement or

relocation, please ask for special technical

service. WariningDon\'t reapair or remove the air conditioner

by ration may cause fire, electric

shock, injury by unit drop and water

leakage. If the air is mixed in the

refrigerant, pressure may increase to

lead to breakage. Thus, please contact

the specialty shop or technical service

center for precautions for Installation1. For the sake of safety, please pay attention to the

following safety precautions WarningUsers are not allowed to install the machine by

themselves.·Improper installation may cause fire, electric shock, water leakage or

WarningIn the event of installation or removing, any substance

other than refrigerant shouldn’t be mixed into the

refrigerant circuit.·If air is mixed in the circuit, system pressure will increase to cause

injury from machine falling.

Please contact the specialty shop or technical service center for machine should be installed in a place which can

support its weight.·If the machine is installed in a place which is not solid enough, there

Don’t fill other refrigerant than specified while installing

or moving the unit.·If so, it may become the cause of problems such as malfunc-will be a risk of injury from machine , false action and mechanical fault and possibly leads to

major safety accidents in some between indoor and outdoor unit shall be connected

properly as specified, and connecting terminals for the

cables be fixed firmly without being affected by external

force.·Poor connection or fixture may cause pumping down the refrigerant, stop the compres-sor before disconnecting the refrigerant pipes.·If the refrigerant pipes are disconnected while the compressor

is running and the stop valve is open, air could be drawn in and

the pressure in the refrigeration cycle could become abnormally

high. This could cause the pipes to burst or injury.·Improper installation may cause fire, electric shock, water leakage or

Installation shall be implemented properly based on

installation instructionsinjury from machine installing the unit, securely connect the refrigerant

pipes before starting the compressor.·If the compressor is started before the refrigerant pipes are

connected and when the stop valve is open, air could be drawn

in and the pressure in the refrigeration cycle could become

abnormally high. This could cause the pipes to burst or ventilate room in the event of refrigerant leakage

during installation.·Exposure of refrigerant to open flame can produce toxic ical work should be performed according to

installation instructions. Be sure to use special power

supply of circuit.·Fire or electric shock may result from insufficient capacity or

incomplete construction for the power supply circuit.43

Safety precautions for Installation

WarningThe electrical cover of indoor unit or the service board

should be installed correctly.·If the cover and the service board are not installed well, fire or electric

shock may result due to entrance of water and ed or specified parts should be used for installation

construction.·Improper parts may cause fire, electric shock, water leakage or injury

from machine the power supply circuit, connection in the middle

section, extension of power cord or use of multi-cable

socket are not suggested.·Poor

t, poor insulation or overload may cause electric

The connection wire from the middle section of connection

wire/signal connection line should not be adopted.·Misoperation

the unit will occur, causing the unit not to operate

Grounding construction shall be done.·The air conditioner socket shall be connected with special earth wire.

·Electric shock may result from no grounding or poor ’t connect the earth wire to gas pipe, tap water pipe, lightning

rod or telephone earth wire.

Don’t install the unit in a place where combustible gas

may leak.·In case the combustible gas leaks and accumulates around the unit,

explosion may result.

A leakage protector shall be installed.·If

may result.

the leakage protector has not been installed, an electric shock

Be sure to implement drainage and piping construction

in terms of installation instructions.·If

indoor

there are improper drainage and

from indoor , furniture will be wet and

piping

contaminated

construction

by water

or inclined

drop

The installation of the unit should be undertalcen strictly

according to GB17790

household and similar air conditioning>.After installation construction, be sure to confirm whether

there are positions in which refrigerant gas leakage occurs.

If the power cord is damaged, be sure to replace it with

special power cord or with special components bought

from manufacturer or service center.

Moreover, if you have no notion of something, contact the

specialty shop for ion for R410A refrigerant systems2-1 Using R410A refigerant air conditionersCautionUse C1220 copper phosphorus (for copper and copper alloy

seamless pipes) to connect the refrigerant pipes. Make

sure the insides of the pipes are clean and do not contain

any harmful contaminants such as sulfuric compounds,

oxidants, debris, or dust. Use pipes with the specified thickness.-Use ester oil, ether oil, alkylbenzene oil (small amount) as

the refrigeration oil applied to the flared sections. If mineral

oil is mixed in the refrigeration oil, oil deterioration may

not use refrigerant other than R410A refrigerant. If

another refrigerant is used, the chlorine will cause the oil to

the following tools specifically designed for use with

r410a REFRIGERANT. The following tools are necessary to

use R410A refrigerant. Contact your nearest dealer for any

(for R410A)Gauge manifoldFlare toolChange hoseSize adjustment gaugeGas leak detectorVacuum pump adapterTorque wrenchElectronic refrigerant charging scaleBe sure to use the correct tools. If dust, debris, or moisture enters

the refrigerant lines, refrigeration oil deterioration may not use a charging cylinder. If a charging cylinder is used,

the composition of the refrigerant will change and the efficiency

will be lowered.2-2 Precautions for devices that use R410A refrigerantCautionWhen installing or moving the air conditioner, use only the

specified refrigerant (R410A) to charge the refrigerant lines. Do

not mix it with any other refrigerant and do not allow air to remain

in the lines. Air enclosed in the lines can cause pressure peaks

resulting in a rupture and other GasMSZ-YK09/12VA-H1 6.35

Thickness0.8mm 9.52

Thickness0.8mmMSZ-YK18VA-H1 6.35

Thickness0.8mm 12.7

Thickness0.8mmDo not use pipes thinner than those specified not share the vacuum pump with R22 refrigerant

systems.44

Safety precautions for ion of installation location3-1 Indoor unit·A place where inlet/outlet airflow shall not be obstructed.·A place where blown cold air can reach each corner of the room.·The maximum distance and maximum height difference between indoor and outdoor unit: Refer to Extreme

Pipe Length.·A solid wall where vibration can’t occur.·A place where direct sunlight is avoided.·A place where drainage becomes easy.·A place where the unit is 1 meter apart from radio and TV or 3 meters apart from antenna.(Otherwise, the TV

image will be disturbed or noise may occur.)·A place where the unit is far away from fluorescent or incandescent lamp(Otherwise, wireless remote controller

may in maloperation).·A place where it’s easy to install and remove the air filter freely.3-2 Outdoor unit·A place with less influence from gale and heavy snow. If the unit is installed in a region of heavy snow, measures shall be

taken for prevention of heavy snow(You are advised to install a covering or base frame).

·A place with good ventilation and less dust.·A place with less rain or less direct sunlight.·A place where operation noise or blown hot air can’t bother neighbor. In order to reduce operation noise or vibration,

you shall install the unit in a solid frame.·A place where there is no leaked combustible gas. When installing the unit in a higher place, you have to fix the foot of

the unit.·Be sure to install the unit horizontally.·Easy for maintenance and repair.

The installation location of the outdoor unit should be at least 3 m away

from the antennas for TV sets,radios, areas where the reception is

weak,provide greater space between the outdoor unit and the antenna

of the affected device if operation of the air conditioner interferes with

radio or TV prevent the

electronic fluorescent

effect of a fluorscent

lamplamp,keep it away

as far as -ventilated

dry placeWall,etc.1m or

moreTo prevent

picture distortion

or noise,keep 1m

or more 10cm ormorephone ormobile phone50cm ormoreRadio3m ormore NoticeDon’t install the air conditioner in the following places.·A place where plenty of machine oil is used.·Seashore with a great deal of salt.·A place where there are hot spring and sulfurized gas.·A place where there is a problem with other environmental

atmosphere.·A place where there are volatile, corrosive and combustible

chemicals.·A place where cranes and ships move.45

Installation lation diagram and accessoryPacking list

(Before installation, users are advised to verify the amount

Connector

Indoor unitStop valveΦ6.35Φ9.52Φ12.7(YK18)-H1Service port

LimitPipe lengthHeight differenceAmount of bends

12m8m10 piecesOutdoor

unitof parts based on the packing list)Amout11521111Installation r

unitAPart nameInstallation No.1Part nameAmoutIndoor unitInstallation plateScrew 4×25mmBattery (No.7)Remote controllerFelt strapGuaranteeOperating andinstalling instructionsOutdoor unit111111111Indoor

Unit2345Connection cableOutdoor

B※Connection pipeunitC※Wall hole sleeveD※E※Wall hole coverPipe strapExtensionF※drainage hoseGH※·Adjustment of refrigerant···If the pipe length exceeds the scope in

Drain PlugPutty

the table below, refrigerant (R410A) should be supplemented. (Filling

refrigerant to the outdoor unit with refrigerant shall be subject to the

following pipe length.)Pipe lengthOver 6 metersTypeMSZ (Inverter)Dosage of refrigerant30g×(pipe length (m)-6)※ This components need to be joint·The unit is equipped with flared joints at indoor/outdoor unit side.·As shown in the figure below, refrigerant pipe is used to connect

·Note: Excessive extension of piping will cause cooling and heating

indoor/outdoor ty to decrease.65mm

or

more,161mm

or

more

for

left

and

left

rear

piping(use

pad).140mmmore

or

1170mor

morm

e2Note:(1) Don\'t use the drainage pipe

connector and rubber stopper

in cold areas. Failure may result

from drainage for installing drainage pipeHD(1) Select a drain hole in the base

for draining and connect the

drainage pipe connector to the

hole.(2) Connect the drainage pipe to the

connector. Keep the drainage

pipe to tilt downsards to make a

smooth draining.5CE4310mm

or

more100mm

or

more10

o0mmr

more20

o0mmr

more350mm

or

more46

Installation instructionsInstallation dimension(Unit:mm)Wall holeWall thicknessDiameter: 65mm

Air inlet315+5.51cmMake about 1cm

part left, cut the outlet2-10×21elliptical(Indoor side)(Wall hole cross

section)350Wall hole sleeveC1-1 HOW TO SWITCH OVER ①The details of slide switch. Remove the front lid.②Be sure to set swith inside the remote controller to an appropriate position inaccordance with the installed position of the indoor unit. If the

swith is not set correctly the air-conditioner not function properly. (refer

to the Page 30)Always use the wall hole sleeve

C, which prevents the connection wires

between indoor and outdoor unit from contacting the metallic parts inside

wall and rodent pest from occurring.

2-3 Specifications for power cord and connection wires·Use special cables for air cord length(Length stretching from left/length

stretching from right)

Connection wires between indoor

and outdoor unit.0.65/1.35mWith a section area of type cableNOTICE:·If the indoor unit unstalled more than 50cm away from

the side walls, cabinets or other neareby objects,set

the side switch to the \"center\" button③Insert the two batteries (AAA) in the place.④Reattach the front lid.⑤Press the RESET button with a pen, SWITCH·Lead out a power cord from the left or right bottom of the indoor unit.2. Installation for indoor unit2-1 Fixing of mounting plate·Look for a structural part (such as a pole) so that you are sure to fix the

Warning·Each air conditioner should be equipped with special power supply line. Power

·mounting panel horizontally. If the indoor unit declines, the furniture

will be wet and contaminated by water drop from the 65mm, a space of

over 161mm shall be made

for piping at left and left

back side (using liner).supply specification should accord with national regulations and be installed

with independent ’t cut off the power cord and connect it to other lines, or fire may ’t bind the rest power cord together, keep it in good order as shown

140mm(from wall)LevelOver 170mm(from wall)Mounting

panel12Fix screw 4×25mm2-4 Connection of indoor/outdoor wires① Open the front panel.② Remove the screw whitch fixed electrical cover to open it.③ Pass the indoor/outdoor unit connecting wire from the back of the

indoor unit,then connect it to the terminal bed. Connect the earth wire to the marked grounding termind on the electrical bow.④ Place the electrical cover securely.(Figure 1)Confirm that the wires have been put into

the terminal block, the central part shall

not be exposed to the order to avoid slight vibration of the mounting plate, Holes marked

with should be fixed, and parts marked with should be also

fixed as possible. When using expansion screws buried into cement wall, you shall use

elliptical holes of 11×20 and 11×26 with 45cm apart from each other to fix

the mounting panel. If the expansion screw is too long, use short screws

sold in market.2-2 Drill holes in wall①Confirm the hole position in wall.②Drill a hole (diameter: 65mm) tilting slightly downwards from inside

③Insert wall hole sleeve

C in the wall hole.④Embed the putter filler

H between wall hole and outside.

Electrical coverConfirm the hole position100mmMounting

panel1Corner panel on

the right bottomIndoor/outdoor unit

connection wiresAInsert a measuring

rule

WarningHole center with OD65mm

Line up the rule

Treat the left hole with the same

way with the aboveIt is forbidden ti hold the bulges of both side of the unit

when moving it.47

Installation instructions Warning·Cables between indoor and outdoor unit shall be connected in good

2-5 Auto restart functionorder using specified cables and connecting terminals be fixed well

without being affected by external force. Fire may result from poor

connection or fixture.·Electrical cover shall be fixed well, otherwise, fire or electric shock may

result from entry of dust and moisture.

·Be sure not to make wrong connection.·Electric shock may result from wrong grounding. When the air conditioner is controlled by the remote controller, indoor

unit electrical board will memorize operation mode, set temperature and

fan speed. If there is a power-off during operation, Auto restart function

is enabled to restart the air conditioner after recovery of power supply. If

the air conditioner operates in the mode of “I FEEL CONTROL” before

power-off, the mode will be memorized. In “I FEEL CONTROL” mode, air

conditioner operation depends on indoor temperature at restarting.

How to set Auto Restart Function Note·Tighten terminal screws to avoid looseness.·After tightening of the screws, pull the wires slightly to verify whether

·If the wires are not connected to the terminal block, the air conditioner

①Remove the front panel

②Remove the screws of electrical cover.③Remove the connector of blade motor from the electrical cover

they are \'t operate the wires of blade motor inside the electrical terminal the temperature sensor from CN111, the MOVE EYE sensor from CN110.④Pull out the electrical board and disconnect the resistance JR07 on it. Warning·Wires between indoor and outdoor terminal block shall be marked with number

Operation①The operation setting is still reserved at power-off.②3 minutes after recovery of power supply, the air conditioner will restart

for corresponding connection.S1S2S3BlackWhiteRedYellow/greenS1S2S3MSZIndoor terminal blockUnscrew terminal screwsBlackWhiteRed4-core rubber coveredOutdoor

terminal

blockIndoor

terminal

blockautomatically according to the -YK09/12VA-H1BlackWhiteRedGreen/yellowMSZ-YK18VA-H1Note:·10 seconds after operating the remote controller, the operation setting

terminal blockWire·When the Auto ON/OFF timer is activated, the timer setting will be

will be r terminal block Warning·Neutral line, live line and earth wire inside power socket shall be connected as

shown in figure reliably without wrong connection and internal short circuit.·Fire may result from wrong led in the event of power-off or power failure. As Auto Restart

function is equipped inside the types, once the power is recovered, the

air conditioner will start to operate three minutes later.·If the air conditioner is turned off by the remote controller before power-off, Auto Restart function will be disabled due to power button’s OFF

status in the remote controller.·In order to prevent impulse current from affecting the power supply,

please arrange a sequence to start other household appliances to

avoid simultaneous power-on.2-6 Piping work····Power supply checkDiagram for power socket in user’s homeGroduing( )·Be sure to place drainage hose under refrigerant ’t upheave or bend the drainage ’t bind up the hose by pulling sure to bind up the drainage hose with commercially available insulated

material when the hose goes through pipes and drainage hose with felt tape

5 and put them into the

pipe keeping section behind the indoor pipeGas pipeNeutral line(N)Live wire(L)Drain PipingFelt tape5Wires for

Aindoor/oudoor unit48

更多推荐

安装,机组,使用,运转,可能,设定