2024年3月14日发(作者:123交通违章查询)

12/18/20

Security Analytics Quick Start Guide

SA-S500 Appliance

1 — Unpack the Appliance

Unpack the shipping package for the appliance and verify it

includes the following contents:

?

SA-S500 appliance

?

(2) AC power cords

?

Null-modem serial cable

?

Grounding Hardware

?

Two/four-post slide-rail kit

?

Accessing Appliance Documentation

?

Software License Agreement

?

Hardware Warranty Information

The following procedure describes a typical deployment for

a single SA-S500-10-CM appliance capturing from a single

SPAN/TAP switch (as shown in the above illustration). For

information on deployments with other SA-S500 appliances,

or configurations with multiple appliances or multiple SPAN/

TAP switches, see the Security Analytics documentation,

available at:

NOTE: Network cables are not included with the appliance.

Make sure to use only straight-through Ethernet cables.

Category 5E cables or better are recommended for

1000Base-T operation. Category 6A cables are

recommended for 10GBase-T operation.

To deploy the appliance and connect cables:

the End User License Agreement (EULA) sticker

from the anti-static bag included with the appliance. By

removing the sticker and installing the product, you are

agreeing to the terms and conditions of the EULA.

t an Ethernet cable to the appliance’s LAN 1:0

port and connect the other end to the SPAN or TAP

switch. The appliance auto-negotiates 100/1000/

10GBase-T speed and duplex settings.

t an Ethernet cable to the appliance’s MGMT 0:0

port and connect the other end of the cable to the

management network switch.

t the included null-modem cable to the appliance’s

DB9 serial port and connect the other end to a serial

terminal or workstation with terminal emulation software.

The serial connection is used to perform the appliance’s

initial configuration.

the lug-equipped end of the included grounding

wire (10 AWG) to both grounding studs on the appliance,

securing it with the star washers and M5 nuts. Attach the

other end of the grounding wire to a proper earth-ground.

t the included AC power cords to the appliance’s

power inlets and connect the other ends of the power

cords to a 120V or 200V power source.

2 — Connect Cables

It is recommended that you plug in cables, verify LEDs, and

configure and license the appliance before mounting it in a

rack. Make sure the appliance is on a flat, level surface

when performing the initial configuration. If you would rather

mount the appliance before performing configuration tasks,

skip to Section 6 — Mount the Appliance.

LAN

Switch

SPAN / Tap

WAN

Router

LANINTERNET

PSU1

eth1

LAN

(1:0)

SA-S500-10-CM

Deployment

PSU2

Serial

Port

eth0

MGMT

(0:0)

Serial

Terminal

MGMT

Switch

Management

Workstation

Security Analytics Deployment

Broadcom, the pulse logo, Connecting everything, Avago Technologies, Avago, the A logo, Symantec, the Symantec logo, the Checkmark logo, Blue Coat, and the Blue Coat

logo are among the trademarks of Broadcom and/or its affiliates in the United States, certain other countries, and/or the EU. Copyright ? 2020 Broadcom. All Rights Reserved.

The term “Broadcom” refers to Broadcom Inc. and/or its subsidiaries. For more information, please visit .

Security Analytics

Quick Start Guide

SA-S500 Appliance Configurations

The SA-S500 is available in the following appliance

configurations with the indicated port enumerations.

?

?

?

?

The power LED turns amber.

Near the end of the boot cycle, the Power LED

alternates between amber and green, indicating an

unconfigured state.

After the boot cycle has completed, the LCD panel

displays information about the appliance, such as

model, serial number, and IP address, which can be

scrolled with the front-panel arrows.

Following the initial configuration and licensing, the

Power LED turns green.

During operation, the front-panel status LEDs indicate the

following states:

LED

Power

Status

Color

Off

Amber

Amber/green

alternating

Green

System

Status

Off

Green

Amber

Amber blinking

Description

Powered off or no power present

Booting

Not yet initialized

Powered on and configured

Powered off or no power present

Normal

System fault or not yet licensed

Critical fault

4 — Perform the Initial

Configuration

You must have the following network information to initialize

the appliance:

3 — Power On the Appliance and

Verify LEDs

To verify the appliance is operational:

m the appliance’s power cords are securely

connected to a power source.

the appliance does not automatically power on, press

the rear soft power switch.

NOTE: The state of the appliance’s soft power switch

(on or off) is retained when power is removed. This may

necessitate pressing the power switch when reapplying

power to the appliance.

the appliance boots, verify the following:

?

?

?

Appliance IP address

Primary DNS server IP

address

Default Gateway IP address

?

?

?

Subnet mask

Link settings (speed and

duplex)

Admin ID and password

To perform the initial configuration for the appliance:

m the appliance’s DB9 serial port is connected to

a serial terminal or workstation with terminal software.

a terminal emulation program, such as Microsoft

HyperTerminal?, PuTTY, Tera Term, or ProComm?,

and configure it to use the following settings:

?

?

?

Baud rate: 9600 bps

Parity: none

Flow control: none

?

?

Data bits: 8

Stop bits: 1

SA-S500 Series

2

Security Analytics

Quick Start Guide

on the appliance (if it is not already powered on)

and log in to the command-line interface (CLI) with

default credentials: admin | Solera

ure the management IP address, netmask, and

gateway with the following CLI command, specifying the

netmask in dotted-decimal format (255.255.255.0):

sudo cfg _ bond _ -i eth0 -n

/ -g

prompted, enter the sudo password: Solera

a browser, navigate to the address just specified,

and log in with default credentials: admin | Solera

prompted, accept the EULA.

the Initial Configuration page, configure the following:

hostname; IP address, mask, and default gateway; up to

three DNS servers; date, time, and time zone; interface

language; and root and admin passwords.

NOTE: For more information, see the Initial Settings

topic in the Security Analytics documentation, available

at:

Save. If there are no errors, you are prompted to

license the appliance.

?

?

?

?

?

?

Click Download DS Seed to download the seed file

() to your workstation.

On a workstation with Internet access, go to:

Type the appliance’s license key, upload ,

and click Submit.

If applicable, select the license type and click Submit.

Save the license file () to the workstation.

Return to the License Details dialog, click Browse, and

select . The license is uploaded and the

appliance automatically reboots.

the appliance has rebooted, select About>

License Details to verify the license.

Download to save an archive copy of the license

file (). Store this file in a secure location that

is not on the appliance.

6 — Mount the Appliance

The slide-rail kit included with the appliance allows it to be

mounted in a 2- or 4-post equipment rack. The slide-rail kit

includes the following parts:

Inner Chassis Rail (2)

5 — License the Appliance

To license the appliance:

completing the initial configuration, you are

prompted with the License Details dialog.

NOTE: You can also update or change an existing

license. To do so, select Menu > Settings > About and

then click License Details.

ve your license key from the Broadcom Support

Portal (/security), as instructed in

the eFulfillment message from Broadcom.

your appliance has Internet access, do the following:

?

Under Retrieve License, enter the License Key and

click Send Request.

?

If applicable, select the license type.

?

The appliance sends the license key and license seed

file to the Symantec license server, which generates the

license file () and returns it to the appliance,

which automatically reboots.

your appliance does not have Internet access, do the

following:

M4x4L screws (4)

M4x5L screws/washers (4)

M6 rack screws/washers (8)

M6 cage nuts (8)

Rail Bracket A (2)

Rail Bracket C (2)

Rail Bracket B (4)

(used only for 2-post racks)

NOTE: Installation of the slide rails requires an M4 nut driver

or adjustable wrench and a #2 Phillips head screwdriver. If

you are working alone, a mechanical lift is also required.

NOTE: The following procedure documents how to install the

appliance in a 4-post equipment rack. For comprehensive

information on rack-mounting the appliance, including other

configurations, see the S-Series WebGuide, available at

.

Rack Warnings and Precautions

CAUTION! Before mounting the appliance:

?

Power off the appliance and disconnect all cables.

?

Verify that the weight of the system does not exceed the

rack’s fully populated weight limit. For more information,

refer to the manufacturer’s instructions included with

the rack.

?

For weight stability, load the rack from the bottom up.

SA-S500 Series

3

Security Analytics

Quick Start Guide

?

?

?

?

Read the “Rack Mount Warnings” section of the Safety

and Compliance Guide.

Take adequate safety and grounding measures to avoid

creating an electrical shock hazard and to prevent

bodily injury.

The appliance is heavy. A two-person lift or mechanical

aid is recommended to lift the appliance from the carton

and install it in the rack.

Do not place objects on the appliance or use it as a

work surface. Its mounting hardware does not support

additional weight.

?

?

Slide the rail toward the rear of the chassis until the

mounting posts snap into place.

Secure each inner rail to the appliance with one M4x4L

screw.

the slide-rail release latches. They should move

smoothly in both directions with minimal effort.

the appliance aside in a safe location.

Install the Slide Rails in a 4-Post Rack

For installation in 4-post equipment racks, the slide rails use

the Bracket_A and Bracket_C assemblies.

To install the slide rails in a 4-post equipment rack:

le the two slide rails:

Attach the Chassis Rails to the Appliance

The slide-rail assemblies come pre-assembled with the

inner chassis rails inside the slide rails. The chassis rails

attach to the appliance chassis. The slide rails are installed

in the equipment rack.

To attach the chassis rails to the appliance:

emble the two slide-rail assemblies:

Bracket_A

Bracket_C

?

?

?

?

?

?

Fully extend each slide rail by sliding out the chassis

rails until they reach the stop.

Press the release tab on the chassis rails and slide

them all the way out.

The chassis rails are symmetrical and can be attached

to either side of the chassis.

?

Loosely attach Bracket_C to the Bracket_A assembly.

Secure the brackets with three M4x5L screws, inserted

through the slot in Bracket_C and screwed into three

holes in Bracket_A.

Make sure the screws are equidistant from each other

so the load will be evenly distributed on the rail. Do not

yet fully tighten the screws.

The precise attachment location of the side-mounting

screws will depend on how far Bracket_C will extend or

retract to fit the rack. It may be necessary to remove

Bracket_C from Bracket_A to determine the proper

installation length.

the two chassis rails to the appliance:

?

Align each rail to the mounting posts on each side of the

chassis.

l the assembled slide rails in the 4-post rack:

?

Secure Bracket_A to the outside front of the rack with

two M6 rack screws. Do not yet fully tighten the screws.

You will do so after the appliance is installed in the rack.

?

Extend or retract Bracket_C to align with the outside

rear of the rack. Secure the bracket with two M6 rack

screws. Do not yet fully tighten the screws. You will do

so after the appliance is installed in the rack.

?

Tighten the three side-mounting M4x5L screws,

securing Bracket_C to Bracket_A, for each slide rail.

SA-S500 Series

4

Security Analytics

Quick Start Guide

t the installed slide rails:

?

Verify the slide rails are even and installed at the same

level in the equipment rack.

?

Make sure the slide rails are free of defect and damage.

Make sure there is no debris in the slide rails.

?

Extend and retract the slide rails to verify smooth

operation and slide-stop operation.

the slide-rail operation:

?

?

?

Press the release tabs on the chassis rails to lock and

unlock the appliance in place.

Push and pull the appliance to verify smooth movement

across the entire slide range.

Carefully pull out the appliance all the way to verify the

slide-stop functionality.

push the appliance all the way into the rack and

tighten the captive thumbscrews on the rack ears to

prevent the appliance from sliding out of the rack.

the appliance is securely installed in the

equipment rack.

ect the cables as documented in Section 2 —

Connect Cables and verify the appliance is functioning as

in Section 3 — Power On the Appliance and Verify LEDs.

7 — Next Steps

?

Install the Appliance into the

Equipment Rack

To install the appliance in the equipment rack and verify

slide-rail operation:

the chassis rails attached to the appliance with the

slide rails in the rack and slide the appliance half-way

into the rack.

the release tabs on the chassis rails to slide the

appliance all the way into the rack.

?

If your Security Analytics system includes external

storage, install the storage arrays per the instructions in

the SA-J5300 Quick Start Guide or SA-SM-48T Quick

Start Guide, available at:

For additional configuration instructions for SA-S500

appliances—including cabling to storage arrays, and

RAID array settings for Capture and Indexing—see the

SA-S500 Configuration Guide, available at:

Symantec Technical Support

?

For Symantec technical support, case management,

licenses, and product downloads, go to

/security

Security Analytics Help and Documentation

?

For Security Analytics help, in the web UI select

Settings > Help > [language].

?

For Security Analytics software documentation, go to

and type “Security” in the

search field, then click Security Analytics.

Appliance Documentation

?

For Symantec appliance documentation, go to

and type “Appliances” in the

search field, then click Hardware Appliances.

Locking tab

the appliance out of the rack, far enough to access

the rack screws. Fully tighten the M6 rack screws

securing the slide rails to the rack.

SA-S500 Series

5

Broadcom reserves the right to make changes without further notice to any products or data herein to improve reliability, function, or design. Information furnished by Broadcom is believed to be accurate and reliable. However, Broadcom does not assume

any liability arising out of the application or use of this information, nor the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. (2020.12.18, 11:59:40)