2024年1月15日发(作者:自动挡开车省油16个技巧)

实用标准文档

第一步,要按照如下方法把IMM2的IP改成下图中的规格。

启动服务器后,可以使用BIOS设置工具管理IMM

网络连接.开启服务器,通电大约两 分钟后,电源控制按钮将会激活,按下开机按钮,就会显示IBM System x Server Firmware

欢迎界面.按下

F1

键.在

Setup utility

主窗口中,选择

System Settings -

Integrated Management Module - Network Configuration.

DHCP Control

with Failover

中有三个

IMM

网络连接选项(Static IP,DHCP Enabled,DHCP

(default).

选择其中一种网络连接方式.如果选择static IP ,须指定IP地址,子网掩码,网

关.(IP address,subnet mask and default gateway).

Sett in gs

保存,退出

Setup utility.

设置完后选择

Save Network

----------------------- 1

Mtnrk CowfifuratliHi

---

Netuork Interface Port

FaiPDver hile

EuiiHfd In fkldrcss

40-r2-E9-?4^D-&E

This option wl)I illou you

to select ijour Systen能畑胆帕就

Network Inter巾u Pn「t?

6

HDSIIUK

DHCP CcHitrol IP Address

Subtil Hdsk Derault

Gdietuy

(Static IP> 132

4G6.70.125 5,255.e

9.6.0.0

in

LomE Link Address

FE8O::42F2:E1FF:也4:9D 6E/S4

1

14-floue Highlight

=Select E^itry Eac-Exlt

(1.506M] DIMH Pbpu lat Inn Change Detected

第二步,要在IBM官网上下载以下两个文件(分别是

UEFI和IMM2的升级文件)文案大全

实用标准文档

IEiM

DEF-I l-las^i Update

以下文件将彌该补「

dn Ibmjw_uefi_vv&15Qc-Z22_anyos_32-64,Ghg(13.2 KB)

i d i ibir fv/ ucJi /7^153c-2.22 j\" /U5 32-0-. \'Eitli 197

&j ibnn uefi we150c-Z22_anyos_32-64

I

I bnn_fw_ uefi_we15Dc-Z22_anyGe_ (3.B2 MB]

以下■文件将丈為该补丁。

i 4 I i bnn-4^31_anyos_noerch. hash (309 bytes)

升城曲的除

码)

ibnn fw imm2 Poo58t 4.21 anya5 rioarGhAixz(yCJ?E MB) i

bm_Jfw_inm2_J, aoaSSt - 4^1_anyos_(0L5a KB) ibdn_1w_rnm2_1aoo&8t-4^^S KB)

i J , ibrn Jw_rnm2_1floo58t-A.31_anyo6_{7.92 KB)

第三步,升级(以下是升级过程)

1.升级

IMM primary

backup bank

1.85

1

)网线连到服务器IMM

端口和笔记本网口,笔记本网络做好如下配置,如已经做好,则跳过第一步文案大全

实用标准文档

* QM liwMt

i iwm

郊时端El ?3M ISO)

鋼(Ml母丽冷

ifc- ?

報澜 \"苦

rfttt

「血牡lJ5

t3G CcrnKScn ;L

AT&T N卅赵

?.frt

忘爭痺m?

■\" ATflT Nrinork

口尸t ?- [^Ml

Errs

ThrikPjd

祖as

?!!自丈迅

粉门那阿Giqihil T

T1SSS;

晒\'

7F ^E\' n\' I\'

[i\' Lnt-dlfl) (11:^ HUf Gifcbit Je-trnk

/>mcch >n

務、

血舟網下耳阳加

*月怡蜜】u奄*

fru血

■曲心曲 榊油

*

4

[EJHT*L 置诫料玉

c

irzti\'iitf\'i

自则D妇

J扫下酬口迪社

H 刚

Q1: 192 .16* .1B .60

麵,耶?戲■

U

』-Lt-lrrr^l恰戒怪玉1

厂皿

自询谆Df.岸错轴:■* ? ‘■

?召圈翩扑宣刃IM擡IQ齣时

SJJJi ■

11

』职耐 吓用逬(itim B^lB耐财;

_酬桂吐戲心

Rcrqlpn

沪\'lm-则;陋??

“ 巧旳 竝皿THGM

2

)上电开机,等待大概

5-6分钟之后,IMM能ping通。可以通过以下步骤测试,打开

CMD命令行

Windows将根挂煤的名称.为SS打幵相应的18序. 文件夹.文栏或Internet磴泻.

打开(O):

emd

+使用言理获限創译此任务欄

歐満

測廉(刃…

敲入ping 192.168.70.125

,如果能连上服务器的Imm,则可以ping通,就是出现下图方框里面的信息。文案大全

实用标准文档

0:MJ3ci\'3\'Mleui.n2>pLn9f 192 ?1G@ ? 70?125

Pinj 192

丄勺玄.1&8_?0.125

192.1&B.70.115

1^2*168.70,125

雷聖具

3

)打开浏览器窗口,地址栏输入

192.168.70.125

,按下回车键

<

L4 ..-t—

fTss _^t 0^

「?■■■■2 2 2 Vr3 ? 3

tan0S

djp n

3

n n

2 2 2

TTL-fc4

TTL-64

TTLf 4

TTL^t4

X

ICE1L* J 1-iM t udir1 rir\'ififa^

I.&M ^lA^dlard Lerftupi&i*#—

IT I44lp Cfrrtfa 0 /. - -

1 』

LQ9

In

Us er name

USERID

P羽钿锁汁

Jractve EesEion brre: ut:

4)

User Name : USERID.

Password : PASSWORD

(“

0” 是数字不是字母)

输入用户名和密码(用户名及密码全是大写)之后,登陆IMM管理界面。

5)鼠标移动到

Server Management

,点击下面的

ServerFirmware文案大全

实用标准文档

IBM Integrated Mtnagenient Modure H

System Status Events ▼ service arwl Support ▼

sttr^T Manarjtmenr -

[MM

Server FirniwAre

View firmware levels and update

firmware

Allows you access mto the oper^tin^ system

of *our syfiteir

Vanous properties ar>d settings related to

v?ur ?yst4m

Power actions sueb as power on, po^er oft,

and restart

Cooling dciriceE nnstaHEd in vaur svstem

System x3630 M4

Add

?淳电m D?$aptNe .?

The System Stitus and Heath pbgm !3rDvd4$ an aVa-glance

o/erv

Rtmote control

Server Properties

Server Power Actionf

System Status

」Fewer:

C?otjng Devices

off

Power M&duie&

| CMITB)

Power moeulei instated m your system

Hairf d-?k driven m^taMed directly m

ycur

| 9|Mtin)Trfomjtfwyi ▼ 11

Disks

Memory

Active Events

Sevsiity * Source D

RAM instali&d irn your systemi

Processors

6)发现机子firmware

的情况如下图所示

Server Firmware

Shaw tiw firrawarp H?v?k cm various wrve-r c^FponantE nduding tW INM

FiriTT^re P pe * Versen

9 0S

Build

DSYT4AA

Release Ddls

22 Apf 2012

16 May 2012

Why 3012

DSA

IMM2 (Active)

IMM 2 (Primary}

IMM2 (Backup)

1 38

138

130

1 0?

102

102

1AOO30C

1AOO30C

^AOO30C 16 May 2012

21 Jun

W?

21 Jun 2012

21 Jun 3012

UFFI (ArtlVfr)

UEFl (PnnTfeary)

RFF117FJS

E3

C112FUS

BEE112FUS

UEFl (BackupJ

文案大全

实用标准文档

7)点击上图的Update Firmware

选项,再点击下图的

Select File,找到升级imm升到1.85的源文件,再点击打文案大全

实用标准文档

Om5eFrnwareFiE

AddrorulOptcw

Select FrnT.;^? Ale

v * re*Dik * ?154u|T?te

■h]\'肛算籲?口址

labite.

W

SntM

SeletTHis

8) 成功上传会出现下面的图片,再点击

next

文案大全

实用标准文档

9)需要两个Action,分别刷Primary和Backup到1.85版本,因此设置为下面图片所示,再点击

n ext

Update Server Hrmware

Choose Frrtwa-e Fib

Additional Options

Sems frmware ttpe ha馆

optorK that

YOUC^I 址HL

PhfartTi Firnrr^^re Flask

< Back NeKt > F -r Cancel

文案大全

Action 1

update the ixirtar^ ban< (de^Ut action) x]

Acban

2

Ufd^te the backup bank I

T S

实用标准文档

10)刷新成功后,会出现下面的图片。再点击

Lpdate Server Firn山白飞

Fi nish

Q?e 升诃盹屜

Perform Ffern^are Flash

gwd \" yorify >lhe Nmgetstpns WiRrinaw.

\'i Addibonal Opttrns

Herfcrm Urnwf^r^ hlasn

Hi Fifniware L^idate

^LECBSS^

Ths

wtad.

gc^ta oocsdura canM^otcd ?uaccs;Mr,Gck

frvh to ub?

]f Uit ?icLdet

i of h e iHM □rnna - it

州II aL-j Le

Trwc^ury to H刪岔t tr* ;剜怡r g :?VM 回百忆

n r*:強

eff&f r.

it ihm tpdctc ndLd?c a Tasfi pf ^LhH ftrnw^e n

胡I

tje nec^satv tu RfiEtatths OG for the t<3dht@

tn take eflact

i c Baft. I

rk

----------

heKt > |

Finish

■3 n c 1*

11

)重启IMM,方法如下图所示

Server and

勺up鼻ort

Strwr

Hanagtimil *

.\'

Svsteni %Wvs Events*

IMM Mgrwg^nwnt *

卜” ■ |

IMH Properties

Server Firmwa re

5h?w tr

Users

V^notis prapefti^ and

障成剖

W

the IMM

Create and modtf user aocourrts that

片il

tiitfc access to the IMM console

Network

wed by

tud-i

it

SNH? ird IDA?

Update Rmrwflre^,,

Network

BLIICI

FmwaTie Typ&

OSA

WM2 (Acthfl]

■ Ver?

IDF

905

138

DS^W

WOO:

22 A

SKiirty

Cwfdur辛

seurrty protwols $udi as SSL

and SSM

View a

oirr*nt

ccnfigLrjTiw stttJV>

Restart Be

卅比

Typolh onlyireeded

w^ien

旳叭encing protrf^ms wM

E iMM

” S?s air current cDfifiguraCon

settings bM

tc d?fai^t h alii^g

Add and namave dctr/atiovi ke)slw

additi/Ml funKCcrdtv

16

v

16

V

诵M

IMM Configuration

wy}

柑M2 (Backup」

f 33

i38

102

iQ2

102

讷OOM

1ADOXB

BEE112FJS

BEE112FUS

GEE112FUS

UEF NActnt}

礙F ?PrKTMy)

21

Ji

21

JI

21

JI

Restfirt IMN

□EF ^Easktip)

R?MT IMM

M f?ctc

AciiwdtiDfi Key Managieniefkt

选择OK

文案大全

实用标准文档

Confirm Restart

Do you want to restart the IMM?

The IMM will be unavailable during the restart* When the restart is

complete, you must log

in to the IMM web console to access the IMM?

OK Cancel

12

)等待5-6分钟之后,才能继续登陆到IMM

界面(可以通过前面提到的

cmd

方法去

pi ng 192.168.70.125

,能

2.升级

UEFI primary

1.30

ping通,则才能登陆IMM),根据前面的方法,查看

server Firmware

,可以看到imm此时的版本信息如下所

,方框里面的三个都是要

1.85.。表示升级IMM

的primary bank

和backup bank

都升级到1.85

承接上面的步骤

13)升级uefi之前,一定要power off

机子,方法如下图所示。 点击左上角的

System Status

,然后在power

文案大全

实用标准文档

Actio ns

下面选择

power off Server Immediately

,如下图方框所示。

System Status Events Service and Support

r Server Management ▼ 1MW Management

System x3630 M4

Add System D&scrptr^e Uams-.-

The System Status and Healti page pr>orvkfes an at-a-glanCE overview of the oper^tiog status of the

昶TVE「in v/hidi this EMM residesB

Commort

System Status

Power: Off

System

state: System power off? State unknown

System Info-niaton ▼ Power Actons ▼

Power On Server Immedtately

Active Events

Power On Server at Specified Dmt日

and Tune

erfly

bou「 _____________________________________________

Power off server Immediately

Hardware Health

Componern T^pe

Coaling Oeviuc1 %

Power Madule^

Procas-\'O1-\'

Merwy

System

Schedule ^aiiy/Weekly Power and Resort Actions

O MormaJ

3 rjArmal

14

)参考前面的步骤

5,先查看server firmware,然后点击下图的

Update Firmware

选项,再点击第二

幅图的Select File,找到升级UEFI升到1.30的源文件,再点击打开。文案大全

实用标准文档

Server Firmware

Show the firrnware l?vels on Vtsrious server cornpaNn^nts. including the 3MM

Update Firmware.…

Firmware Type ■ Version-

Build

D5YT9AA

屜IMW Dale

DSA

IMM2 |Activ?)

INM2 iPnmarv)

IM M2 (Backup}

UEFI fAclive}

UEFL [Prmafyj.

& 0&

1.C5

1.B5

1.C5

i C2

1.C2

1 02

22 Apr 2012

14 No> 2012

14 hm. 20t2

1AOO34Z

1 AGO 342

1AOO342

BEE112f=US

?EE112FUS

8EE112HJS

14 Nov 2012

21 Jun 2012

21 Jun 2012

21 Jun 2012 UEFI (Backup]

Up^teSflnef Fmwart

怦祕r卄.

季血and

丫押尙

SfitatFimr/je Rle

Seectlhft WaiefhthMyx\'wstito

杷岂翊懣KM

「;

r merit t 7;J8

upd?tt

靈 *

J ?

^fnPrirwMFlwh

M瓒note M

加叫空、

puoo効砒

Ittisswjrw

-ibnLH_bn!24c?l J0jnR244uu

JOL

select He >M

TU5 .M:帥_*感&°:加-価上“0?44皿 ?

nra i

文案大全

实用标准文档

15

)成功上传之后会出现下图,点击

next

Jpdate Server Rrmware

Owse Frmw烈傩 Upload and Verify

\"电

finwijo

ts sing

⑷曜a You M haw n ocportini^ tc

旧rfy *T is th& OTKt tie prior to :he tolling i

DGX』记

Vr?-

K-

crtxetiw^

Optbis

Perfyn F rw

活馆

F lash

汕“品LJ utJbdd.

The Mnmare nage \'iDm_fw_ueli_Deei24c-1 .M_anycE_32-6^

BHnx;s5i^i udoutd ard

呵F冈

R

The upba^ed file

昭》s (Mectaj

as 4 UEF1 frmwars

勺匕 耐h Bufel IL BEE12OJS. The CLirent ID n the

PKTJT^ .$ BffillSFJS -

The ciirrt Bud ID m the bxlw

蹿

n EffLLSFUS .

If t饬

is ciirect, dO ths Next xutri co corKCue the frTmae uocate E^oofilure.

< ^KiHrN^NO t

1 Cancel

16

)只选择升级Primary bank

,设置成如下图所示,再点击

next文案大全

实用标准文档

17

)成功升级完成后,会出现下图,点击

finish

文案大全

实用标准文档

18

)拔掉电源线,等待几秒(一定要断电),重新插上启动机子。等待机子出现

项,则按下键盘的

F1,然后依次选择

System In formatio n->Product Data,

不是1.30,需要再次断电重启, 重启之后,同样的方法,在Product Data

UEFI界面并可以看到

F1选

查看UEFI当前的版本,如果

里面,就可以看到UEFI显示1.30

的升的版本,说明1.30的版本已经active激活了。完成

UEFI primary bank

级。

文案大全

实用标准文档

7) 此时会看到屏幕上很多代码在扫,如下所示,表示正在退出

BOMC

Uctiia* hu cnplrUd -

mknM .

* *)Ml?h flJ? V IlMctdni

P ■1|| | |

文案大全

更多推荐

点击,升级,出现,所示,下图,机子,看到,笔记本